Removal of As(V) by PVDF hollow fibers membrane contactors using Aliquat-336 as extractant

被引:50
作者
Bey, Said [2 ]
Criscuoli, Alessandra [1 ]
Figoli, Alberto [1 ]
Leopold, Agnieszka [3 ]
Simone, Silvia [1 ]
Benamor, Mohammed [2 ]
Drioli, Enrico [1 ]
机构
[1] Inst Membrane Technol ITM CNR, I-87036 Arcavacata Di Rende, CS, Italy
[2] Bejaia Univ, Mat Organ Lab, Targa Ouzemour 06000, Algeria
[3] Polytech Univ Barcelona, Barcelona, Spain
关键词
As(V); Aliquat; 336; Hollow fiber membrane contactors; Non dispersive solvent extraction; PVDF; SUPPORTED LIQUID-MEMBRANE; POLYMER INCLUSION MEMBRANES; ULTRAFILTRATION MEMBRANES; HYPOCHLORITE; TRANSPORT; RECOVERY; BLENDS; ION;
D O I
10.1016/j.desal.2010.09.027
中图分类号
TQ [化学工业];
学科分类号
081705 [工业催化];
摘要
In this work the removal of As(V) from an aqueous stream by non-dispersive solvent extraction in a hollow fibre membrane contactor was investigated To this purpose microporous hydrophobic poly(vinylidene fluoride) hollow fibres were prepared by the dry/wet spinning technique Fibres were spun changing the pore forming additives to obtain micro-porous sponge-like structure membranes with pore diameters of about 0 2 mu m and porosity of 80% The produced fibres were used to perform As(V) extraction experiments in a membrane contactor device using Aliquat-336 as extractant Different tests were carried out in order to study the effect of temperature initial concentration pH of the feed solution and membrane properties The results showed that the extraction of As(V) by non dispersive solvent extraction was influenced by the pH of the feed with an optimum reached for neutral values increased with the arsenic content in the feed and was not affected by temperature The extraction was favoured by working with thinner membranes The highest removal of arsenic achieved was around 70% after 6 h of operation The produced fibres kept their performance for all the experimental activity giving reproducible results with time (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:193 / 200
页数:8
相关论文
共 35 条
[1]
Baker W.R., 2000, MEMBRANE TECHNOLOGY
[2]
Arsenic(V) removal with polymer inclusion membranes from sulfuric acid media using DBBP as carrier [J].
Ballinas, MD ;
De San Miguel, ER ;
Rodríguez, MTD ;
Silva, O ;
Muñoz, M ;
De Gyves, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (03) :886-891
[3]
Transport of lithium through a supported liquid membrane of LIX54 and TOPO in kerosene [J].
Bansal, B ;
Chen, XD ;
Hossain, MM .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2005, 44 (12) :1327-1336
[4]
Effect of extractant on arsenic(V) recovery from sulfuric acid solutions [J].
Bogacki, MB ;
Wisniewski, M ;
Szymanowski, J .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 228 (1-2) :57-61
[5]
Cadmium removal using hollow fiber membrane with organic extractant [J].
Choi, DW ;
Kim, YH .
KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2003, 20 (04) :768-771
[6]
Drioli E., 2006, Membrane Contactors: Fundamentals, Applications and Potentialities
[7]
Continuous operation of membrane processes for the treatment of industrial effluents [J].
Eliceche, AM ;
Corvalan, SM ;
Ortiz, I .
COMPUTERS & CHEMICAL ENGINEERING, 2002, 26 (4-5) :555-561
[8]
Nonlinear two-phase equilibrium model for the binding of arsenic anions to cationic micelles [J].
Ergican, Erdogan ;
Gecol, Hatice .
JOURNAL OF MEMBRANE SCIENCE, 2008, 325 (01) :69-80
[9]
REVIEW OF ARSENIC CYCLE IN NATURAL WATERS [J].
FERGUSON, JF ;
GAVIS, J .
WATER RESEARCH, 1972, 6 (11) :1259-&
[10]
Hollow fiber membrane contactors [J].
Gabelman, A ;
Hwang, ST .
JOURNAL OF MEMBRANE SCIENCE, 1999, 159 (1-2) :61-106