A survey of wind speeds in indoor workplaces

被引:179
作者
Baldwin, PEJ [1 ]
Maynard, AD [1 ]
机构
[1] Hlth & Safety Execut, Hlth & Safety Lab, Sheffield S3 7HQ, S Yorkshire, England
关键词
D O I
10.1016/S0003-4878(98)00031-3
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The applicability of the inhalable convention for sampling aerosols relies on its being a valid model for typical sampling environments. The current convention is based on measurements carried out in external wind speeds between 1 and 4 m.s(-1). However these measurements show a degree of wind speed dependence, and it is uncertain at present how valid the convention is for describing human aspiration efficiency outside these wind speed limits. Following concerns that wind speeds in many indoor workplaces may be significantly below; this range, measurements have been made in 55 work areas covering a wide range of workplaces, Measurements have concentrated on 'background' wind speeds where the influence of specific air movement sources is minimised, The pooled wind speed measurements show a highly skewed distribution with an arithmetic mean of approximately 0.3 m.s(-1). Approximately 85% of all individual measurements were below this mean value, No obvious correlation was found between wind speed distribution parameters and industry type, room size or ventilation type, A limited number of comparisons were made between static anemometers and devices mounted on workers. It was found that modal wind speeds experience by workers were typically 0.05 m.s(-1) higher than those measured using a static anemometer. These measurements agreed well with previously published data for similar workplaces as well as houses. Crown copyright (C) 1998 Published by Elsevier Science Ltd on behalf of British Occupational Hygiene Society.
引用
收藏
页码:303 / 313
页数:11
相关论文
共 17 条
[1]  
ANDRIA GD, 1983, AEROSOLS MINING IND, P235
[2]  
[Anonymous], 1988, ASHR T
[3]  
Armbruster L., 1982, INHALED PARTICLES, P21
[4]  
BALDWIN PEJ, 1997, P 11 ANN C UK AER SO
[5]  
BERRY RD, 1989, IRLDS893 HSE INT REP
[6]  
*BSI, 1993, 481 BS EN
[7]  
Hanzawa H., 1987, ASHRAE T, V93, P524, DOI DOI 10.1016/J.EPSL.2013.05.019
[8]   A collaborative European study of personal inhalable aerosol sampler performance [J].
Kenny, LC ;
Aitken, R ;
Chalmers, C ;
Fabries, JF ;
GonzalezFernandez, E ;
Kromhout, H ;
Liden, G ;
Mark, D ;
Riediger, G ;
Prodi, V .
ANNALS OF OCCUPATIONAL HYGIENE, 1997, 41 (02) :135-153
[9]   TURBULENT AIR-FLOW MEASUREMENTS IN VENTILATED SPACES [J].
KOVANEN, K ;
SEPPANEN, O ;
SIREN, K ;
MAJANEN, A .
ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) :621-626
[10]   AIR VELOCITIES INSIDE DOMESTIC ENVIRONMENTS - AN IMPORTANT PARAMETER IN THE STUDY OF INDOOR AIR-QUALITY AND CLIMATE [J].
MATTHEWS, TG ;
THOMPSON, CV ;
WILSON, DL ;
HAWTHORNE, AR ;
MAGE, DT .
ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) :545-550