Tris(2,2'-bipyridyl)ruthenium(Il)-zirconia-nafion composite films applied as solid-state electrochemiluminescence detector for capillary electrophoresis

被引:61
作者
Ding, SN [1 ]
Xu, JJ [1 ]
Chen, HY [1 ]
机构
[1] Nanjing Univ, Dept Chem, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
关键词
capillary electrophoresis; solid-state electrochemiluminescence; zirconia-nafion composite;
D O I
10.1002/elps.200410324
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The major goal of this work was to develop a new solid-state electrochemiluminescence (ECL) detector suitable for capillary electrophoresis (CE). The detector was fabricated by coating a sol-gel derived zirconia (ZrO2)-Nafion composite film on a graphite electrode, then the zirconia-Nafion modified electrode was immersed in tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) solution to immobilize this active chemiluminescence reagent. The voltammetric and ECL behaviors of the detector were investigated and optimized in tripropylamine solution. The ratio of 53% for zirconia in the zirconia-Nafion composite provided the highest luminescence intensity of immobilized Ru(bpy)(3)(2+). The ECL can maintain its stability very well in the phosphate solution in the period of 5-90 h when the solid-state ECL detector was immersed in the solution all the time. The optimum distance of capillary outlet to the solid-state ECL detector has been found to be ca. 50-80 Pm for a 75 mu m capillary. The effects of ionic strength and pH of ECL solution on peak height were investigated. The CE with solid-state ECL detector system was successfully used to detect tripropylamine, lidocaine, and proline. The detection limits (S/N = 3) were 5 x 10(-9) mol(.)L(-1) for tripropylamine, 1 x 10(-8) mol(.)L(-1) for lidocaine and 5 x 10(-6) mol(.)L(-1) for proline, and the linear ranges were from 1.0 x 10(-8) to 1.0 x 10(-5) mol(.)L(-1) for tripropylamine, 5.0 x 10(-7) mol(.)L(-1) to 1.0 x 10(-5) mol(.)L(-1) for lidocaine and 1.0 x 10(-5) to 1.0 x 10(-3) mol(.)L(-1) for proline, respectively.
引用
收藏
页码:1737 / 1744
页数:8
相关论文
共 56 条
[1]   A wireless electrochemiluminescence detector applied to direct and indirect detection for electrophoresis on a microfabricated glass device [J].
Arora, A ;
Eijkel, JCT ;
Morf, WE ;
Manz, A .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3282-3288
[2]   Chemiluminescent detection of amines and amino acids using in situ generated Ru(bpy)33+ following separation by capillary electrophoresis [J].
Bobbitt, DR ;
Jackson, WA ;
Hendrickson, HP .
TALANTA, 1998, 46 (04) :565-572
[3]   ROLE OF ELECTRON-DONATING WITHDRAWING CHARACTER, PH, AND STOICHIOMETRY ON THE CHEMILUMINESCENT REACTION OF TRIS(2,2'-BIPYRIDYL)RUTHENIUM(III) WITH AMINO-ACIDS [J].
BRUNE, SN ;
BOBBITT, DR .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :166-170
[4]  
Cao WD, 2002, ELECTROPHORESIS, V23, P3683, DOI 10.1002/1522-2683(200211)23:21<3683::AID-ELPS3683>3.0.CO
[5]  
2-F
[6]  
Cao WD, 2002, ELECTROANAL, V14, P1571, DOI 10.1002/1521-4109(200211)14:22<1571::AID-ELAN1571>3.0.CO
[7]  
2-X
[8]  
Cao WD, 2002, ELECTROPHORESIS, V23, P3692, DOI 10.1002/1522-2683(200211)23:21<3692::AID-ELPS3692>3.0.CO
[9]  
2-J
[10]   Enantiomeric separation of tramadol hydrochloride and its metabolites by cyclodextrin-mediated capillary zone electrophoresis [J].
Chan, ECY ;
Ho, PC .
JOURNAL OF CHROMATOGRAPHY B, 1998, 707 (1-2) :287-294