Smoke filling time for a room due to a small fire: The effect of ceiling height to floor width aspect ratio

被引:27
作者
Kaye, N. B. [1 ]
Hunt, G. R. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Civil & Environm Engn, London SW7 2AZ, England
关键词
smoke plumes; smoke filling rate; room aspect ratio; available safe egress time;
D O I
10.1016/j.firesaf.2006.12.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
We consider the filling of a room with smoke from a small, centrally located floor fire. We present theoretical arguments for the behaviour of the filling time relative to the idealised 'filling box time' [Baines WD, Turner JS. Turbulent buoyant convection from a source in a confined region. J Fluid Mech 1969;37:51-80] as a function of the room height to width aspect ratio. Initially, the rate at which the smoke layer deepens is shown to be more rapid for relatively wide rooms (large aspect ratio). However, at larger times, relatively tall rooms (small aspect ratio) fill more rapidly due to large scale overturning and engulfing of ambient fluid. A series of experiments were performed to verify these results and showed good qualitative agreement with our theoretical predictions. The experiments were also used to evaluate the extent of deviation of the actual smoke front position from the idealised filling box model as a function of the aspect ratio. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:329 / 339
页数:11
相关论文
共 14 条
[1]   TURBULENT BUOYANT CONVECTION FROM A SOURCE IN A CONFINED REGION [J].
BAINES, WD ;
TURNER, JS .
JOURNAL OF FLUID MECHANICS, 1969, 37 :51-+
[2]  
Barnett S.J, 1991, THESIS U CAMBRIDGE
[3]   HEAT CONVECTION AND BUOYANCY EFFECTS IN FLUIDS [J].
BATCHELOR, GK .
QUARTERLY JOURNAL OF THE ROYAL METEOROLOGICAL SOCIETY, 1954, 80 (345) :339-+
[4]   SPREAD OF A NEGATIVELY BUOYANT PLUME IN A CALM ENVIRONMENT [J].
BRITTER, RE .
ATMOSPHERIC ENVIRONMENT, 1979, 13 (09) :1241-1247
[5]   The mixing in a room by a localized finite-mass-flux source of buoyancy [J].
Caulfield, CP ;
Woods, AW .
JOURNAL OF FLUID MECHANICS, 2002, 471 (471) :33-50
[6]   CEILING JET-DRIVEN WALL FLOWS IN COMPARTMENT FIRES [J].
COOPER, LY .
COMBUSTION SCIENCE AND TECHNOLOGY, 1988, 62 (4-6) :285-296
[7]   EFFECT OF OPPOSING BUOYANCY ON THE FLOW IN FREE AND WALL JETS [J].
GOLDMAN, D ;
JALURIA, Y .
JOURNAL OF FLUID MECHANICS, 1986, 166 :41-56
[8]   Virtual origin correction for lazy turbulent plumes [J].
Hunt, GR ;
Kaye, NG .
JOURNAL OF FLUID MECHANICS, 2001, 435 :377-396
[9]   Experimental studies on natural smoke filling in atrium due to a shop fire [J].
Huo, R ;
Chow, WK ;
Jin, XH ;
Li, YZ ;
Fong, NK .
BUILDING AND ENVIRONMENT, 2005, 40 (09) :1185-1193
[10]   Time-dependent flows in an emptying filling box [J].
Kaye, NB ;
Hunt, GR .
JOURNAL OF FLUID MECHANICS, 2004, 520 :135-156