Biofilm formation and multiplication of Legionella in a model warm water system with pipes of copper, stainless steel and cross-linked polyethylene

被引:142
作者
van der Kooij, D
Veenendaal, HR
Scheffer, WJH
机构
[1] Kiwa Water Res, NL-3430 BB Nieuwegein, Netherlands
[2] UNETO, VNI, NL-2715 CA Zoetermeer, Netherlands
关键词
Legionella; warm water; biofilm formation; ATP; copper; stainless steel; PEX;
D O I
10.1016/j.watres.2005.04.075
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Legionella pneumophila was grown in a model warm water system with pipes of copper (Cu), stainless steel (SS) and cross-linked polyethylene (PEX) during recirculation of tap water at 25-3 degrees C. Subsequently, domestic use of warm (37 degrees C) water was simulated using tap water with a low AOC concentration (< 10 mu g C/L). Two times each week the temperature of the water in the electric heaters (not in the pipes) was elevated to 70 degrees C for 30 min. ATP concentrations in the water sampled from the pipes over a 2-year period were significantly different for the pipe materials, with median values of 2.1 ng/l (Cu), 2.5 ng/l (SS) and 4.5 ng/l (PEX), respectively. Median values of the biofilm concentration were similar on Cu and SS (about 630 pg ATP/cm(2)) and 1870 pg ATP/cm(2) on PEX. Legionella multiplied in these biofilms and median values of Legionella concentrations in water were 1500 CFU/l(Cu) and about 4300 CFU/l for SS and PEX. Legionella to ATP ratios in water had median values of about 0.8 CFU/pg. Hot water flushing (70 degrees C) of the pipes on day 552, followed by 2 weeks of recirculation at 37 degrees C, caused strongly increased concentrations of ATP (up to 300 ng/l) and Legionella (> 10(7) CFU/l), with about 100 CFU/pg ATP. Concentrations declined to original levels within 1 week of domestic water use, etc. Legionella concentrations in water and biofilms were at the same levels for all materials after 2 years. Hence, copper temporarily limited the growth of Legionella under the applied conditions and a rapid biomass development strongly increased the Legionella to ATP ratio. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2789 / 2798
页数:10
相关论文
共 33 条
[1]  
Abu Kwaik Y, 1998, APPL ENVIRON MICROB, V64, P3127
[2]   Bulk water phase and biofilm growth in drinking water at low nutrient conditions [J].
Boe-Hansen, R ;
Albrechtsen, HJ ;
Arvin, E ;
Jorgensen, C .
WATER RESEARCH, 2002, 36 (18) :4477-4486
[3]   ROLE OF STAGNATION AND OBSTRUCTION OF WATER-FLOW IN ISOLATION OF LEGIONELLA-PNEUMOPHILA FROM HOSPITAL PLUMBING [J].
CIESIELSKI, CA ;
BLASER, MJ ;
WANG, WLL .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1984, 48 (05) :984-987
[4]   ISOLATION OF LEGIONELLA-PNEUMOPHILA FROM HOSPITAL SHOWER HEADS [J].
CORDES, LG ;
WIESENTHAL, AM ;
GORMAN, GW ;
PHAIR, JP ;
SOMMERS, HM ;
BROWN, A ;
YU, VL ;
MAGNUSSEN, MH ;
MEYER, RD ;
WOLF, JS ;
SHANDS, KN ;
FRASER, DW .
ANNALS OF INTERNAL MEDICINE, 1981, 94 (02) :195-197
[5]   IMPROVED SEMISELECTIVE MEDIUM FOR ISOLATION OF LEGIONELLA-PNEUMOPHILA FROM CONTAMINATED CLINICAL AND ENVIRONMENTAL SPECIMENS [J].
EDELSTEIN, PH .
JOURNAL OF CLINICAL MICROBIOLOGY, 1981, 14 (03) :298-303
[6]  
FISHERHOCH SP, 1981, LANCET, V1, P932
[7]   MEASUREMENT OF ADENOSINE TRIPHOSPHATE IN OCEAN AND ITS ECOLOGICAL SIGNIFICANCE [J].
HOLMHANSEN, O ;
BOOTH, CR .
LIMNOLOGY AND OCEANOGRAPHY, 1966, 11 (04) :510-+
[8]   CELLULAR NUCLEOTIDE MEASUREMENTS AND APPLICATIONS IN MICROBIAL ECOLOGY [J].
KARL, DM .
MICROBIOLOGICAL REVIEWS, 1980, 44 (04) :739-796
[9]  
KOOL JL, 2000, THESIS AMSTERDAM
[10]   Intracellular proliferation of Legionella pneumophila in Hartmannella vermiformis in aquatic biofilms grown on plasticized polyvinyl chloride [J].
Kuiper, MW ;
Wullings, BA ;
Akkermans, ADL ;
Beumer, RR ;
van der Kooij, D .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (11) :6826-6833