Initial experience with X-ray CT based attenuation correction in myocardial perfusion SPECT imaging using a combined SPECT/CT system

被引:52
作者
Utsunomiya, D
Tomiguchi, S
Shiraishi, S
Yamada, K
Honda, T
Kawanaka, K
Kojima, A
Awai, K
Yamashita, Y
机构
[1] Saiseikai Kumamoto Hosp, Diagnost Imaging Ctr, Kumamoto 8614193, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto 860, Japan
[3] Kumamoto Univ, Grad Sch Med Sci, Dept Cardiovasc Med, Kumamoto 860, Japan
[4] Kumamoto Univ, Inst Resource Dev & Anal, Kumamoto 860, Japan
关键词
coronary artery disease; myocardial perfusion SPECT; TI-201; attenuation correction; CT;
D O I
10.1007/BF02985576
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Attenuation artifacts adversely affect the diagnostic accuracy of myocardial perfusion imaging. We assessed the clinical usefulness of X-ray CT based attenuation correction (AC) in patients undergoing myocardial perfusion imaging by comparing their myocardial AC- and non-corrected (NC) SPECT images with the coronary angiography (CAG). Methods: We retrospectively reviewed the myocardial SPECT images of 30 patients (18 men, 12 women; mean age 68 years). Thirteen of 30 patients with coronary artery disease (CAD) and 17 without CAD were confirmed by CAG. They underwent sequential CT and myocardial SPECT imaging with thallium-201 (111 MBq) under an exercise or pharmacological stress protocol using our combined SPECT/ CT system. Two readers reviewed the myocardial SPECT images for the presence of CAD on a 4-point scale where 1 = normal, 2 = probably normal, 3 = probably abnormal, and 4 = abnormal. Two reading sessions were held. First, non-corrected (NC)-SPECT and second, AC-SPECT images using X-ray CT images were interpreted. Interobserver variability was assessed with kappa statistics. Diagnostic performance (accuracy) of coronary arterial stenosis was compared between AC- and NC-images. Results: Interobserver agreement for visual assessment was substantial or almost perfect. For AC-images, the observer consensus for analysis was 0.84 for the LAD-, 0.87 for the LCX-, and 0.71 for the RCA-territory. For NC-images, it was 0.91, 0.71, and 0.78. AC resulted in statistically significant improvements in overall diagnostic accuracy (sensitivity/ specificity/accuracy = 76%/93%/89%, 67%/86%/81%, respectively, for AC- and NC-images). Conclusions: Because of an increase in the specificity, diagnostic accuracy was significantly increased on AC-images. These preliminary data suggest that X-ray CT based AC in myocardial SPECT imaging has the potential to develop into a reliable clinical technique.
引用
收藏
页码:485 / 489
页数:5
相关论文
共 23 条
[1]   QUANTITATIVE ROTATIONAL TL-201 TOMOGRAPHY FOR IDENTIFYING AND LOCALIZING CORONARY-ARTERY DISEASE [J].
DEPASQUALE, EE ;
NODY, AC ;
DEPUEY, EG ;
GARCIA, EV ;
PILCHER, G ;
BREDLAU, C ;
ROUBIN, G ;
GOBER, A ;
GRUENTZIG, A ;
DAMATO, P ;
BERGER, HJ .
CIRCULATION, 1988, 77 (02) :316-327
[2]   Updated imaging guidelines for nuclear cardiology procedures, part 1 [J].
DePuey, EG ;
Garcia, EV .
JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (01) :G3-G58
[3]   Improved detection of left main coronary artery disease with attenuation-corrected SPECT [J].
Duvernoy, CS ;
Ficaro, EP ;
Karabajakian, MZ ;
Rose, PA ;
Corbett, JR .
JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (06) :639-648
[4]  
FICARO EP, 1995, J NUCL MED, V36, P921
[5]  
FICARO EP, 1994, J NUCL MED, V35, P652
[7]  
Harel F, 2001, J NUCL MED, V42, P1451
[8]   Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging [J].
Hendel, RC ;
Berman, DS ;
Cullom, SJ ;
Follansbee, W ;
Heller, GV ;
Kiat, H ;
Groch, MW ;
Mahmarian, JJ .
CIRCULATION, 1999, 99 (21) :2742-2749
[9]  
JASZCZAK RJ, 1993, J NUCL MED, V34, P1577
[10]   Correction of nonuniform attenuation and image fusion in SPECT imaging by means of separate X-ray CT [J].
Kashiwagi, T ;
Yutani, K ;
Fukuchi, M ;
Naruse, H ;
Iwasaki, T ;
Yokozuka, K ;
Inoue, S ;
Kondo, S .
ANNALS OF NUCLEAR MEDICINE, 2002, 16 (04) :255-261