A novel amperometric sensor and chromatographic detector for determination of parathion

被引:34
作者
Li, CY [1 ]
Wang, CF [1 ]
Ma, Y [1 ]
Bao, W [1 ]
Hu, SH [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
carbon nano-tube; nafion; sensor; parathion; high-performance liquid chromatography;
D O I
10.1007/s00216-004-2978-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel amperometric sensor and chromatographic detector for determination of parathion has been fabricated from a multi-wall carbon nano-tube (MWCNT)/Nafion film-modified glassy-carbon electrode (GCE). The electrochemical response to parathion at the MWCNT/Nafion film electrode was investigated by cyclic voltammetry and linear sweep voltammetry. The redox current of parathion at the MWCNT/Nafion film electrode was significantly higher than that at the bare GCE, the MWCNT-modified GCE, and the Nafion-modified GCE. The results indicated that the MWCNT/Nafion film had an efficient electrocatalytic effect on the electrochemical response to parathion. The peak current was proportional to the concentration of parathion in the range 5.0x10(-9) -2.0x10(-1). The detection limit was 1.0x10(-9) mol L-1 (after 120 s accumulation). In high-performance liquid chromatography with electrochemical detection (HPLC-ED) a stable and sensitive current response was obtained for parathion at the MWCNT/Nafion film electrode. The linear range for parathion was over four orders of magnitude and the detection limit was 6.0x10(-9) mol L-1. Application of the method for determination of parathion in rice was satisfactory.
引用
收藏
页码:1049 / 1055
页数:7
相关论文
共 33 条
  • [1] Nanotubes from carbon
    Ajayan, PM
    [J]. CHEMICAL REVIEWS, 1999, 99 (07) : 1787 - 1799
  • [2] Carbon nanotube actuators
    Baughman, RH
    Cui, CX
    Zakhidov, AA
    Iqbal, Z
    Barisci, JN
    Spinks, GM
    Wallace, GG
    Mazzoldi, A
    De Rossi, D
    Rinzler, AG
    Jaschinski, O
    Roth, S
    Kertesz, M
    [J]. SCIENCE, 1999, 284 (5418) : 1340 - 1344
  • [3] In situ detection of cytochrome c adsorption with single walled carbon nanotube device
    Boussaad, S
    Tao, NJ
    Zhang, R
    Hopson, T
    Nagahara, LA
    [J]. CHEMICAL COMMUNICATIONS, 2003, (13) : 1502 - 1503
  • [4] Carbon nanotube electrode for oxidation of dopamine
    Britto, PJ
    Santhanam, KSV
    Ajayan, PM
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1996, 41 (01): : 121 - 125
  • [5] Carbon nanotubule membranes for electrochemical energy storage and production
    Che, GL
    Lakshmi, BB
    Fisher, ER
    Martin, CR
    [J]. NATURE, 1998, 393 (6683) : 346 - 349
  • [6] High H2 uptake by alkali-doped carbon nanotubes under ambient pressure and moderate temperatures
    Chen, P
    Wu, X
    Lin, J
    Tan, KL
    [J]. SCIENCE, 1999, 285 (5424) : 91 - 93
  • [7] A CARBON NANOTUBE FIELD-EMISSION ELECTRON SOURCE
    DEHEER, WA
    CHATELAIN, A
    UGARTE, D
    [J]. SCIENCE, 1995, 270 (5239) : 1179 - 1180
  • [8] Disposable potentiometric enzyme sensor for direct determination of organophosphorus insecticides
    Gäberlein, S
    Knoll, M
    Spener, F
    Zaborosch, C
    [J]. ANALYST, 2000, 125 (12) : 2274 - 2279
  • [9] VOLTAMMETRIC DETERMINATION OF METHYL PARATHION, ORTHO, META AND PARA NITROPHENOL WITH A CARBON PASTE ELECTRODE MODIFIED WITH C-18
    HERNANDEZ, L
    HERNANDEZ, P
    VICENTE, J
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (11): : 712 - 715
  • [10] Carbon nanotubes: past, present, and future
    Iijima, S
    [J]. PHYSICA B-CONDENSED MATTER, 2002, 323 (1-4) : 1 - 5