摘要
Transient-evoked otoacoustic emissions (TEOAE) to clicks and to 500- and 2000-Hz brief tones were measured in 72 normal-hearing and hearing-impaired subjects (86 ears). The TEOAE's reproducibility parameter was used for the analyses. The purpose of the investigation was to determine which stimuli best predicted the presence of sensorineural hearing loss in a frequency-specific manner at 500, 1000, 2000, and 4000 Hz. Analyses of the TEOAEs filtered into frequency-specific bands showed that separation of normal and impaired ears at 1000, 2000 and 4000 Hz was best achieved by TEOAEs evoked by clicks. Identification of hearing loss al 500 Hz was best obtained using 500-Hz tone-evoked TEOAEs filtered using a band centered at 500 Hz. Octave- and half-octave-wide bands identified hearing loss equally well. An analysis sweep time of 20 ms provided slightly better results compared to 30 ms, except for 500 Hz, where the 30-ms sweep time slightly improved the identification of hearing loss. Increases in the audiometric criterion did not yield better test performance once hearing loss exceeded 20 dB HL. The findings from this study suggest that the combination of bandpass-filtered TEOAEs to clicks and TEOAEs to 500-Hz tones identifies with reasonable accuracy ears with sensorineural hearing loss at 500, 1000, 2000, and 4000 Hz.
引用
收藏
页码:125 / 136
页数:12
相关论文
共 51 条
[1]   TRANSIENT EVOKED OTOACOUSTIC EMISSIONS - CLINICAL-APPLICATIONS AND TECHNICAL CONSIDERATIONS [J].
ABDO, MH ;
FEGHALI, JG ;
STAPELLS, DR .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 1993, 25 (1-3) :61-71
[2]  
ABDO MH, 1994, OTOLARYNGOLOGY HEAD, V111, P98
[3]  
ABOD MH, 1992, ABSTR 15 MIDW RES M, P151
[4]  
American National Standard Institute, 1969, AM NAT STAND SPEC AU
[5]   QUANTITATIVE ASSESSMENT OF HUMAN COCHLEAR FUNCTION BY EVOKED OTOACOUSTIC EMISSIONS [J].
AVAN, P ;
BONFILS, P ;
LOTH, D ;
NARCY, P ;
TROTOUX, J .
HEARING RESEARCH, 1991, 52 (01) :99-112
[6]   CLINICAL-APPLICATIONS OF EVOKED ACOUSTIC EMISSIONS - RESULTS IN NORMALLY HEARING AND HEARING-IMPAIRED SUBJECTS [J].
BONFILS, P ;
UZIEL, A .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1989, 98 (05) :326-331
[7]   CLINICAL-SIGNIFICANCE OF OTOACOUSTIC EMISSIONS - A PERSPECTIVE [J].
BONFILS, P ;
AVAN, P ;
FRANCOIS, M ;
MARIE, P ;
TROTOUX, J ;
NARCY, P .
EAR AND HEARING, 1990, 11 (02) :155-158
[8]  
BRAY P, 1987, British Journal of Audiology, V21, P191, DOI 10.3109/03005368709076405
[9]   OUTER HAIR CELL ELECTROMOTILITY AND OTOACOUSTIC EMISSIONS [J].
BROWNELL, WE .
EAR AND HEARING, 1990, 11 (02) :82-92
[10]  
COLLET L, 1989, ARCH OTOLARYNGOL, V115, P1060