How do we assess hospital cleaning? A proposal for microbiological standards for surface hygiene in hospitals

被引:290
作者
Dancer, SJ [1 ]
机构
[1] Scottish Ctr Infect & Environm Hlth, Glasgow G3 7LN, Lanark, Scotland
关键词
hospital cleaning; mcrobiological standards; surface hygiene;
D O I
10.1016/j.jhin.2003.09.017
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Increasing numbers of hospital-acquired infections have generated much attention over the last decade. The public has linked the so-called 'superbugs' with their experience of dirty hospitals, but the precise role of cleaning in the control of these organisms in unknown. Hence the importance of a clean environment is likely to remain speculative unless it becomes an evidence-based science. This proposal is a call for bacteriological standards with which to assess clinical surface hygiene in hospitals, based on those used by the food industry. The first standard concerns any finding of a specific 'indicator' organism, the presence of which suggests a requirement for increased cleaning. Indicators would include Staphylococcus aureus, including methicillin-resistant S. aureus, Clostridium difficile, vancomycin-resistant enterococci and various Gram-negative bacilli. The second standard concerns a quantitative aerobic colony count of < 5 cfu/cm(2) on frequent hand touch surfaces in hospitals. The principle relates to modern risk management systems such as HACCP, and reflects the fact that pathogens of concern are widespread. Further work is required to evaluate and refine these standards and define the infection risk from the hospital environment. (C) 2003 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:10 / 15
页数:6
相关论文
共 58 条
  • [1] Relationship between environmental fungal contamination and the incidence of invasive aspergillosis in haematology patients
    Alberti, C
    Bouakline, A
    Ribaud, P
    Lacroix, C
    Rousselot, P
    Leblanc, T
    Derouin, F
    [J]. JOURNAL OF HOSPITAL INFECTION, 2001, 48 (03) : 198 - 206
  • [2] [Anonymous], NAT STAND CLEANL NHS
  • [3] [Anonymous], BR J INFECT CONTROL
  • [4] BERMAN DS, 1986, NEW ENGL J MED, V315, P514
  • [5] Environmental contamination due to methicillin-resistant Staphylococcus aureus (MRSA)
    Blythe, D.
    Keenlyside, D.
    Dawson, S. J.
    Galloway, A.
    [J]. JOURNAL OF HOSPITAL INFECTION, 1998, 38 (01) : 67 - 69
  • [6] Boyce JM, 1997, INFECT CONT HOSP EP, V18, P622
  • [7] Computer keyboards and faucet handles as reservoirs of nosocomial pathogens in the intensive care unit
    Bures, S
    Fishbain, JT
    Uyehara, CFT
    Parker, JM
    Berg, BW
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2000, 28 (06) : 465 - 471
  • [8] HANDS AS ROUTE OF TRANSMISSION FOR KLEBSIELLA SPECIES
    CASEWELL, M
    PHILLIPS, I
    [J]. BRITISH MEDICAL JOURNAL, 1977, 2 (6098) : 1315 - 1317
  • [9] Centers for Disease Control and Prevention, 2003, MMWR-MORBID MORTAL W, V52, P1
  • [10] Management of hospital outbreaks of gastro-enteritis due to small round structured viruses
    Chadwick, PR
    Beards, G
    Brown, D
    Caul, EO
    Cheesbrough, J
    Clarke, I
    Curry, A
    O'Brien, S
    Quigley, K
    Sellwood, J
    Westmoreland, D
    [J]. JOURNAL OF HOSPITAL INFECTION, 2000, 45 (01) : 1 - 10