Hemodynamic effects of the vacuum-assisted closure device on open mediastinal wounds

被引:29
作者
Conquest, AM
Garofalo, JH
Maziarz, DM
Mendelson, MG
Sun, YS
Wooden, WA
Meadows, WM
Nifong, W
Chitwood, WR
机构
[1] E Carolina Univ, Brody Sch Med, Dept Surg, Greenville, NC 27858 USA
[2] Univ S Florida, Tampa, FL USA
关键词
vacuum-assisted closure device; post-sternotomy wound infection; open mediastinal wounds;
D O I
10.1016/S0022-4804(03)00331-7
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. Application of the Vacuum-Assisted Closure device (VAC to open sternal wounds has negative hemodynamic effects. We hypothesized that the interposition of a muscle flap attenuates these negative hemodynamic effects. Materials and methods. After institutional approval, monitoring lines were placed in anesthetized, ventilated pigs. Through a median sternotomy, sonometric crystals were strategically positioned around the left ventricle. A rectus flap was rotated over the mediastinal wound, and the VAC was placed over the flap. After baseline measurements, a vacuum of 125 mmHg [Group (GP) 1, n = 51 or 50 mmHg (GP2, n = 6) was initiated. Hemodynamics were recorded every 15 min for 1.5 h, and 15 min after cessation of the vacuum therapy. GP3 (n = 6) underwent intermittent VAC cycling (on 5 min/off 2 min). Significance determined by t test. Results. While non-flapped animals had significant detriment in both left ventricular filling volume and cardiac output, flapped animals had insignificant depression of both parameters. Conclusion. Application of muscle flaps to sternal wounds prior to VAC therapy significantly attenuates the negative hemodynamic effects seen when the VAC is used alone. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:209 / 213
页数:5
相关论文
共 7 条
[1]   Spontaneous right ventricular rupture after sternal dehiscence: A preventable complication? [J].
Arbulu, A ;
Gursel, E ;
Camero, LG ;
Asfaw, I ;
Stephenson, LW .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1996, 10 (02) :110-115
[2]  
BJERNO T, 1990, Ugeskrift for Laeger, V152, P3699
[3]   The vacuum-assisted closure device as a bridge to sternal wound closure [J].
Hersh, RE ;
Jack, JM ;
Dahman, MI ;
Morgan, RF ;
Drake, DB .
ANNALS OF PLASTIC SURGERY, 2001, 46 (03) :250-254
[4]   Management of the infected median sternotomy wound with muscle flaps - The emory 20-year experience [J].
Jones, G ;
Jurkiewicz, MJ ;
Bostwick, J ;
Wood, R ;
Bried, JT ;
Culbertson, J ;
Howell, R ;
Eaves, F ;
Carlson, G ;
Nahai, F .
ANNALS OF SURGERY, 1997, 225 (06) :766-776
[5]   Vacuum-assisted closure: A new method for wound control and treatment: Animal studies and basic foundation [J].
Morykwas, MJ ;
Argenta, LC ;
SheltonBrown, EI ;
McGuirt, W .
ANNALS OF PLASTIC SURGERY, 1997, 38 (06) :553-562
[6]   MEDIASTINAL INFECTION AFTER CARDIAC-SURGERY [J].
SARR, MG ;
GOTT, VL ;
TOWNSEND, TR .
ANNALS OF THORACIC SURGERY, 1984, 38 (04) :415-423
[7]  
SONG DH, 2001, PLASTIC RECONSTRUCT, V111, P92