The stiffness of bone marrow cell-knit composites is increased during mechanical load

被引:19
作者
Bruinink, A [1 ]
Siragusano, D [1 ]
Ettel, G [1 ]
Brandsberg, T [1 ]
Brandsberg, F [1 ]
Petitmermet, M [1 ]
Müller, B [1 ]
Mayer, J [1 ]
Wintermantel, E [1 ]
机构
[1] Swiss Fed Inst Technol, Swiss Fed Inst Technol, Dept Mat Biocompatible Mat Sci & Engn, CH-8952 Schlieren, Switzerland
关键词
mechanical load; culture; bone marrow; knit; stiffness; strain;
D O I
10.1016/S0142-9612(01)00069-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel device for mechanical stimulation of primary adult rat bone marrow cells cultured on three-dimensional knitted textiles has been prototyped. A method has been developed ensuring a well-defined, high-density, and reproducible cell seeding on the knitted fabric. After culturing for 18-52 days the cell-knit composites were subjected to uniaxial 2% stretching and relaxation. The frequency was altered between 0.1 Hz (196 min, loading phase) and 0.01 Hz (360 min, resting phase). Identically treated knits without cells exhibited a slight stiffness reduction, whereas the stiffness of knits with cells increased from cycle to cycle. The stiffness increase was found to depend on the duration of the culture period before mechanical loading. Our data suggest that the extracellular matrix deposited by the cells on the knit and intact microtubuli of living cells cause the observed stiffness increase. In comparison to the unstrained static cell-knit composites cell proliferation and bone cell differentiation were reduced by the mechanical load. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:3169 / 3178
页数:10
相关论文
共 32 条
  • [1] DEDIFFERENTIATED CHONDROCYTES REEXPRESS THE DIFFERENTIATED COLLAGEN PHENOTYPE WHEN CULTURED IN AGAROSE GELS
    BENYA, PD
    SHAFFER, JD
    [J]. CELL, 1982, 30 (01) : 215 - 224
  • [2] Brown RA, 1998, J CELL PHYSIOL, V175, P323, DOI 10.1002/(SICI)1097-4652(199806)175:3<323::AID-JCP10>3.0.CO
  • [3] 2-6
  • [4] Bruinink A., 1992, BRAIN BITS PIECES, P23
  • [5] In vivo measurement of human tibial strains during vigorous activity
    Burr, DB
    Milgrom, C
    Fyhrie, D
    Forwood, M
    Nyska, M
    Finestone, A
    Hoshaw, S
    Saiag, E
    Simkin, A
    [J]. BONE, 1996, 18 (05) : 405 - 410
  • [6] Claes LE, 1998, CLIN ORTHOP RELAT R, pS132
  • [7] The estrogen receptor's involvement in osteoblasts' adaptive response to mechanical strain
    Damien, E
    Price, JS
    Lanyon, LE
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (08) : 1275 - 1282
  • [8] MECHANOTRANSDUCTION AND THE FUNCTIONAL-RESPONSE OF BONE TO MECHANICAL STRAIN
    DUNCAN, RL
    TURNER, CH
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1995, 57 (05) : 344 - 358
  • [9] Eastwood M, 1998, CELL MOTIL CYTOSKEL, V40, P13, DOI 10.1002/(SICI)1097-0169(1998)40:1<13::AID-CM2>3.0.CO
  • [10] 2-G