Rapid automated method for on-site determination of sulfadiazine in fish farming: a stainless steel veterinary syringe coated with a selective membrane of PVC serving as a potentiometric detector in a flow-injection-analysis system

被引:10
作者
Almeida, S. A. A. [2 ,3 ,4 ]
Amorim, L. R. [1 ]
Heitor, A. H. [3 ]
Montenegro, M. C. B. S. M. [4 ]
Barbosa, J. [5 ]
Sa, L. C. [5 ]
Sales, M. G. F. [1 ,2 ]
机构
[1] Inst Super Engn Porto, P-4200072 Oporto, Portugal
[2] Inst Super Engn Porto, BioMark ISEP, P-420002 Oporto, Portugal
[3] Inst Nacl Saude Dr Ricardo Jorge Porto, INSA Porto, P-1649016 Lisbon, Portugal
[4] Univ Porto, REQUIMTE Dept Ciencias Quim, Fac Farm, P-4050047 Oporto, Portugal
[5] Lab Nacl Invest Vet, LNIV, P-4485655 Vairao, Portugal
关键词
Sulfadiazine; Chemical sensor; Aquaculture; Flow-injection analysis; Potentiometry; LIQUID-CHROMATOGRAPHY; ELECTRODES; AQUACULTURE; TRIMETHOPRIM; ANTIBIOTICS; RESISTANCE; SENSORS;
D O I
10.1007/s00216-011-5441-1
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% o-nitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade(-1) down to 1.0 x 10(-5) mol L-1, with a limit of detection of 3.1 x 10(-6) mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography-tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.
引用
收藏
页码:3355 / 3365
页数:11
相关论文
共 32 条
[1]
Antimicrobial resistance in bacteria isolated from aquaculture sources in Australia [J].
Akinbowale, O. L. ;
Peng, H. ;
Barton, M. D. .
JOURNAL OF APPLIED MICROBIOLOGY, 2006, 100 (05) :1103-1113
[2]
Alexander PW, 1998, ELECTROANAL, V10, P707, DOI 10.1002/(SICI)1521-4109(199808)10:10<707::AID-ELAN707>3.3.CO
[3]
2-M
[4]
Sulfadiazine-selective determination in aquaculture environment: Selective potentiometric transduction by neutral or charged ionophores [J].
Almeida, S. A. A. ;
Heitor, A. M. ;
Montenegro, M. C. B. S. M. ;
Sales, M. G. F. .
TALANTA, 2011, 85 (03) :1508-1516
[5]
[Anonymous], DIELECTRIC CONSTANT
[6]
INDOMETHACIN ION-SELECTIVE ELECTRODE BASED ON A BIS(TRIPHENYLPHOSPHORANYLIDENE)AMMONIUM INDOMETHACIN COMPLEX [J].
AUBECK, R ;
BRAUCHLE, C ;
HAMPP, N .
ANALYST, 1991, 116 (08) :811-814
[7]
Potentiometric sensors for trace-level analysis [J].
Bakker, E ;
Pretsch, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (03) :199-207
[8]
Determination of sulfonamide antibiotics in wastewater: A comparison of solid phase microextraction and solid phase extraction methods [J].
Balakrishnan, Vimal K. ;
Terry, Ken A. ;
Toito, John .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1131 (1-2) :1-10
[9]
Comparison of multi-sulfonamide biosensor immunoassays [J].
Bienenmann-Ploum, M ;
Korpimäki, T ;
Haasnoot, W ;
Kohen, F .
ANALYTICA CHIMICA ACTA, 2005, 529 (1-2) :115-122
[10]
Veterinary medicines in the environment [J].
Boxall, ABA ;
Fogg, LA ;
Blackwell, PA ;
Kay, P ;
Pemberton, EJ ;
Croxford, A .
REVIEWS OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, VOL 180, 2004, 180 :1-91