Inductively coupled plasma mass spectrometry as a simple, rapid, and inexpensive method for determination of uranium in urine and fresh water: Comparison with LIF

被引:43
作者
Karpas, Z
Halicz, L
Roiz, J
Marko, R
Katorza, E
Lorber, A
Goldbart, Z
机构
[1] NUCL RES CTR, DEPT ANALYT CHEM, NEGEV, ISRAEL
[2] GEOL SURVEY ISRAEL, IL-95501 JERUSALEM, ISRAEL
[3] NUCL RES CTR, MED LAB, NEGEV, ISRAEL
来源
HEALTH PHYSICS | 1996年 / 71卷 / 06期
关键词
uranium; excretion; urinary; exposure; occupational; nuclear power industry;
D O I
10.1097/00004032-199612000-00004
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A simple method, based on inductively coupled plasma mass spectrometry, for determination of uranium in urine at levels that indicate occupational exposure, is presented. Sample preparation involves a fifty-fold dilution of the urine by nitric acid (2% HNO3) and no other chemical treatment or separation. The analysis itself is completed in under 3 min. The analytical procedure is fully automated so that a technician may perform over 100 analyses per day. With proper control of the blank contribution, a lower limit of detection of 3 ng L(-1) in the original urine sample was achieved. Uranium concentrations in the range 6-30 ng L(-1) were found in urine samples of people that are not occupationally exposed. The validity of the results was demonstrated through measurement of standards, controlled uranium addition experiments and, at higher concentrations, by comparison with results obtained by an independent method based on laser induced fluorescence. The laser induced fluorescence technique was found to be sufficient for detection of occupational exposure at an action level of 1.5 mu g L(-1). Use of internal standards, indium, and thallium, improved quantification by about 10%, but was not deemed necessary for routine analysis. The inductively coupled plasma mass spectrometry is also ideally suited for monitoring uranium in fresh water and drinking water, as no sample dilution is required and the lower limit of detection is below 0.15 ng L(-1).
引用
收藏
页码:879 / 885
页数:7
相关论文
共 41 条
[21]   DETERMINATION OF GROSS ALPHA-ACTIVITY IN URINE BY MICROPRECIPITATION WITH LAF3 AND ALPHA-SPECTROMETRY [J].
JIA, GG ;
BAZZARI, S ;
MICCI, F ;
TESTA, C .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1994, 178 (01) :11-18
[22]   DETERMINING PICOGRAM QUANTITIES OF U IN HUMAN-URINE BY THERMAL IONIZATION MASS-SPECTROMETRY [J].
KELLY, WR ;
FASSETT, JD ;
HOTES, SA .
HEALTH PHYSICS, 1987, 52 (03) :331-336
[23]   AN INTERCOMPARISON STUDY OF NP-237 DETERMINATION IN ARTIFICIAL URINE SAMPLES [J].
LEE, SC ;
HUTCHINSON, JMR ;
INN, KGW ;
THEIN, M .
HEALTH PHYSICS, 1995, 68 (03) :350-358
[24]   BASIS FOR THE ICRPS AGE-SPECIFIC BIOKINETIC MODEL FOR URANIUM [J].
LEGGETT, RW .
HEALTH PHYSICS, 1994, 67 (06) :589-610
[25]   FRACTIONAL ABSORPTION OF INGESTED URANIUM IN HUMANS [J].
LEGGETT, RW ;
HARRISON, JD .
HEALTH PHYSICS, 1995, 68 (04) :484-498
[26]   DIURNAL URINARY VOLUME AND URANIUM OUTPUT IN URANIUM WORKERS AND UNEXPOSED CONTROLS [J].
MEDLEY, DW ;
KATHREN, RL ;
MILLER, AG .
HEALTH PHYSICS, 1994, 67 (02) :122-130
[27]   DEVELOPMENT OF A RAPID, ECONOMICAL AND SENSITIVE METHOD FOR THE ROUTINE DETERMINATION OF EXCRETED URANIUM IN URINE [J].
MILLER, TJ .
ANALYTICAL LETTERS, 1991, 24 (04) :657-664
[28]   A RAPID METHOD FOR DETERMINING NANOGRAM QUANTITIES OF URANIUM IN URINE USING THE KINETIC PHOSPHORESCENCE ANALYZER [J].
MOORE, LL ;
WILLIAMS, RL .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 156 (01) :223-233
[29]   DETERMINATION OF URANIUM IN SOLUTION AT THE NG-1-1 LEVEL BY TIME-RESOLVED LASER-INDUCED SPECTROFLUORIMETRY - APPLICATION TO GEOLOGICAL SAMPLES [J].
MOULIN, C ;
BEAUCAIRE, C ;
DECAMBOX, P ;
MAUCHIEN, P .
ANALYTICA CHIMICA ACTA, 1990, 238 (02) :291-296
[30]  
NAPIER WA, 1984, P INT C OCC RAD SAF, V1, P265