Morphometric analysis of particulate debris extracted by four different embolic protection devices from coronary arteries, aortocoronary saphenous vein conduits, and carotid arteries

被引:41
作者
Quan, VH
Huynh, R
Seifert, PA
Kuchela, A
Chen, WH
Sütsch, G
Eisenhauer, AC
Rogers, C
机构
[1] Harvard Univ, Div Cardiovasc, Brigham & Womens Hosp, Med Sch,Cardiac Catheterizat Lab, Boston, MA 02115 USA
[2] MIT, Div Hlth Sci & Technol, Cambridge, MA 02139 USA
[3] Medtronic Inc, Danvers, MA USA
[4] Univ Zurich Hosp, Dept Med, Div Cardiol, CH-8091 Zurich, Switzerland
[5] Queen Mary Hosp, Dept Med, Div Cardiol, Hong Kong, Hong Kong, Peoples R China
关键词
D O I
10.1016/j.amjcard.2005.02.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Different embolic protection devices have been introduced for endovascular interventions: filters or balloon occlusion and aspiration systems. Despite widening use in a variety of vascular beds and clinical syndromes, little is known about the particulate burden liberated from different vascular beds and caught by different protection devices. We performed histologic and morphometric analyses of particulate debris captured during stenting of degenerated saphenous vein bypass grafts and native coronary arteries during acute myocardial infarction or during elective intervention and carotid arteries to assess the relative performance of different protection devices. We analyzed 232 interventions (90 saphenous vein bypass grafts, 77 native coronary arteries, and 65 carotid arteries) with 4 different devices (65 FilterWires, 99 Interceptors, 41 GuardWires, and 27 Proxis catheters) using the RapidVue particle analyzer. No difference in embolic volume retrieved was demonstrated between devices in saphenous vein bypass grafts and carotid interventions. A smaller volume of particulate debris was retrieved by the GuardWire compared with the FilterWire and the Proxis catheter in native coronary artery interventions. The Interceptor and the GuardWire captured more smaller particles than did the FilterWire or Proxis catheter. During saphenous vein bypass graft or carotid intervention, different embolic protection strategies were performed similarly. in native coronary artery stenting, however, proximal embolic protection retrieved larger amounts of debris than did distal filters or occlusion devices. These data may allow greater tailoring of embolic protection device development and application in specific anatomic locales. (c) 2005 by Excerpta Medica Inc.
引用
收藏
页码:1415 / 1419
页数:5
相关论文
共 12 条
[1]   Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts [J].
Baim, DS ;
Wahr, D ;
George, B ;
Leon, MB ;
Greenberg, J ;
Cutlip, DE ;
Kaya, U ;
Popma, JJ ;
Ho, KKL ;
Kuntz, RE .
CIRCULATION, 2002, 105 (11) :1285-1290
[2]   Coronary no-reflow is caused by shedding of active tissue factor from dissected atherosclerotic plaque [J].
Bonderman, D ;
Teml, A ;
Jakowitsch, J ;
Adlbrecht, C ;
Gyöngyösi, M ;
Sperker, W ;
Lass, H ;
Mosgoeller, W ;
Glogar, DH ;
Probst, P ;
Maurer, G ;
Nemerson, Y ;
Lang, IM .
BLOOD, 2002, 99 (08) :2794-2800
[3]   Renal angioplasty and stenting under protection: The way for the future? [J].
Henry, M ;
Henry, I ;
Klonaris, C ;
Polydorou, A ;
Rath, P ;
Lakshmi, G ;
Rajacopal, S ;
Hugel, M .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 60 (03) :299-312
[4]   Evaluation of a distal protection filter device in patients with acute myocardial infarction:: Final results of the DIPLOMAT study [J].
Lefèvre, T ;
Guyon, P ;
Reimers, B ;
Fauvel, JM ;
Pansieri, M ;
Dewez, MP .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :72A-72A
[5]   Mechanical prevention of distal embolization during primary angioplasty - Safety, feasibility, and impact on myocardial reperfusion [J].
Limbruno, U ;
Micheli, A ;
De Carlo, M ;
Amoroso, G ;
Rossini, R ;
Palagi, C ;
Di Bello, V ;
Petronio, AS ;
Fontanini, G ;
Mariani, M .
CIRCULATION, 2003, 108 (02) :171-176
[6]   Comparison of various cerebral protection devices used for carotid artery stent placement:: An in vitro experiment [J].
Müller-Hülsbeck, S ;
Jahnke, T ;
Liess, C ;
Glass, C ;
Grimm, J ;
Heller, M .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (05) :613-620
[7]   Comparison and modification of two cerebral protection devices used for carotid angioplasty:: In vitro experiment [J].
Müller-Hülsbeck, S ;
Grimm, J ;
Liess, C ;
Hedderich, J ;
Bergmeyer, M ;
Heller, M .
RADIOLOGY, 2002, 225 (01) :289-294
[8]   Embolic protection with filtering or occlusion balloons during saphenous vein graft stenting retrieves identical volumes and sizes of particulate debris [J].
Rogers, C ;
Huynh, R ;
Seifert, PA ;
Chevalier, B ;
Schofer, J ;
Edelman, ER ;
Toegel, G ;
Kuchela, A ;
Woupio, A ;
Kuntz, RE ;
Macon, ND .
CIRCULATION, 2004, 109 (14) :1735-1740
[9]   Primary angioplasty in acute myocardial infarction with distal protection of the microcirculation: Principal results from the prospective, randomized EMERALD trial [J].
Stone, GW ;
Webb, J ;
Cox, DA ;
Brodie, BR ;
Qureshi, M ;
Dulas, D ;
Kalynych, A ;
Turco, M ;
Schultheiss, HP ;
Rutherford, B ;
Kruckoff, M ;
Gibbons, R ;
Lansky, AJ ;
Pop, R ;
Mehran, R ;
Jones, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :285A-286A
[10]   Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts [J].
Stone, GW ;
Rogers, C ;
Hermiller, J ;
Feldman, R ;
Hall, P ;
Haber, R ;
Masud, A ;
Cambier, P ;
Caputo, RP ;
Turco, M ;
Kovach, R ;
Brodie, B ;
Kuntz, RE ;
Popma, JJ ;
Ramee, S ;
Cox, DA .
CIRCULATION, 2003, 108 (05) :548-553