Separating processes within a trial in event-related functional MRI - II. Analysis

被引:244
作者
Ollinger, JM
Corbetta, M
Shulman, GL
机构
[1] Washington Univ, Sch Med, Neuroimaging Lab, Dept Radiol, St Louis, MO 63110 USA
[2] Washington Univ, Dept Neurol, St Louis, MO 63110 USA
关键词
D O I
10.1006/nimg.2000.0711
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Many cognitive processes occur on time scales that can significantly affect the shape of the blood oxygenation level-dependent (BOLD) response in event-related functional MRI. This shape can be estimated from event related designs, even if these processes occur in a fixed temporal sequence (J. M. Ollinger, G. L. Shulman, and M. Corbetta. 2001. NeuroImage 13: 210-217). Several important considerations come into play when interpreting these time courses. First, in single subjects, correlations among neighboring time points give the noise a smooth appearance that can be confused with changes in the BOLD response. Second, the variance and degree of correlation among estimated time courses are strongly influenced by the timing of the experimental design. Simulations show that optimal results are obtained if the intertrial intervals are as short as possible, if they follow an exponential distribution with at least three distinct values, and if 40% of the trials are partial trials. These results are not particularly sensitive to the fraction of partial trials, so accurate estimation of time courses can be obtained with lower percentages of partial trials (20-25%). Third, statistical maps can be formed from F statistics computed with the extra sum of square principle or by t statistics computed from the cross-correlation of the time courses with a model for the hemodynamic response. The latter method relies on an accurate model for the hemodynamic response. The most robust model among those tested was a single gamma function. Finally, the power spectrum of the measured BOLD signal in rapid event-related paradigms is similar to that of the noise. Nevertheless, high-pass filtering is desirable if the appropriate model for the hemodynamic response is used, (C) 2001 Academic Press.
引用
收藏
页码:218 / 229
页数:12
相关论文
共 40 条
  • [1] The variability of human, BOLD hemodynamic responses
    Aguirre, GK
    Zarahn, E
    D'Esposito, M
    [J]. NEUROIMAGE, 1998, 8 (04) : 360 - 369
  • [2] Beck J.V., 1977, Parameter Estimation in Engineering and Science
  • [3] FUNCTIONAL CONNECTIVITY IN THE MOTOR CORTEX OF RESTING HUMAN BRAIN USING ECHO-PLANAR MRI
    BISWAL, B
    YETKIN, FZ
    HAUGHTON, VM
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) : 537 - 541
  • [4] SOME THEOREMS ON QUADRATIC FORMS APPLIED IN THE STUDY OF ANALYSIS OF VARIANCE PROBLEMS .1. EFFECT OF INEQUALITY OF VARIANCE IN THE ONE-WAY CLASSIFICATION
    BOX, GEP
    [J]. ANNALS OF MATHEMATICAL STATISTICS, 1954, 25 (02): : 290 - 302
  • [5] Linear systems analysis of functional magnetic resonance imaging in human V1
    Boynton, GM
    Engel, SA
    Glover, GH
    Heeger, DJ
    [J]. JOURNAL OF NEUROSCIENCE, 1996, 16 (13) : 4207 - 4221
  • [6] Functional-anatomic correlates of object priming in humans revealed by rapid presentation event-related fMRI
    Buckner, RL
    Goodman, J
    Burock, M
    Rotte, M
    Koutstaal, W
    Schacter, D
    Rosen, B
    Dale, AM
    [J]. NEURON, 1998, 20 (02) : 285 - 296
  • [7] Detection of cortical activation during averaged single trials of a cognitive task using functional magnetic resonance imaging
    Buckner, RL
    Bandettini, PA
    OCraven, KM
    Savoy, RL
    Petersen, SE
    Raichle, ME
    Rosen, BR
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (25) : 14878 - 14883
  • [8] Noise suppression digital filter for functional magnetic resonance imaging based on image reference data
    Buonocore, MH
    Maddock, RJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) : 456 - 469
  • [9] BUROCK MA, 1998, DESIGN STAT ANAL FMR, P77
  • [10] CLARK VP, 1997, NEUROIMAGE, V5, pS50