Fluorescent microthermal imaging - Theory and methodology for achieving high thermal resolution images

被引:26
作者
Barton, DL
Tangyunyong, P
机构
[1] Electron. Quality/Reliability Center, Sandia National Laboratories, Failure Analysis Department 2275, Albuquerque, NM 87185-5800
关键词
D O I
10.1016/0167-9317(95)00349-5
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The fluorescent microthermal imaging technique (FMI) involves coating a sample surface with an inorganic-based thin film that, upon exposure to UV light, emits temperature-dependent fluorescence [1-8]. FMI offers the ability to create thermal maps of integrated circuits with a thermal resolution theoretically limited to 1 m degrees C and a spatial resolution which is diffraction-limited to 0.3 mu m. Even though the fluorescent microthermal imaging (FMI) technique has been around for more than a decade, many factors that can significantly affect the thermal image quality have not been systematically studied and characterized. After a brief review of FMI theory, we will present our recent results demonstrating for the first time three important factors that have a dramatic impact on the thermal quality and sensitivity of FMI. First, the limitations imparted by photon shot noise and improvement in the signal-to-noise ratio realized through signal averaging will be discussed. Second, ultraviolet bleaching, an unavoidable problem with FMI as it currently is performed, will be characterized to identify ways to minimize its effect. Finally, the impact of film dilution on thermal sensitivity will be discussed.
引用
收藏
页码:271 / 279
页数:9
相关论文
共 8 条
[1]  
BARTON DL, 1994, P 20 ISTFA, P87
[2]  
BHAUMIK M, 1964, J CHEM PHYS, V40
[3]  
Bowen E. J., 1959, J PHYS CHEM, V63, P4
[4]  
CROSBY G, J CHEM PHYS, V34, P1961
[5]   REMOTE THERMAL IMAGING WITH 0.7-MU-M SPATIAL-RESOLUTION USING TEMPERATURE-DEPENDENT FLUORESCENT THIN-FILMS [J].
KOLODNER, P ;
TYSON, JA .
APPLIED PHYSICS LETTERS, 1983, 42 (01) :117-119
[6]   MICROSCOPIC FLUORESCENT IMAGING OF SURFACE-TEMPERATURE PROFILES WITH 0.01-DEGREES-C RESOLUTION [J].
KOLODNER, P ;
TYSON, JA .
APPLIED PHYSICS LETTERS, 1982, 40 (09) :782-784
[7]  
KOLODNER P, 1983, APPL PHYS LETT, V42
[8]   FLUORESCENCE OF EUROPIUM THENOYLTRIFLUOROACETONATE .1. EVALUATION OF LASER THRESHOLD PARAMETERS [J].
WINSTON, H ;
MARSH, OJ ;
TELK, CL ;
SUZUKI, CK .
JOURNAL OF CHEMICAL PHYSICS, 1963, 39 (02) :267-&