Retention of ionizable compounds on high-performance liquid chromatography VII.: Characterization of the retention of ionic solutes in a C18 column by mass spectrometry with electrospray ionization

被引:24
作者
Rosés, M [1 ]
Oumada, FZ [1 ]
Bosch, E [1 ]
机构
[1] Univ Barcelona, Dept Quim Analit, E-08028 Barcelona, Spain
关键词
charge exclusion; mobile phase composition; retention behavior; inorganic cations; tetrabutylammonium bromide;
D O I
10.1016/S0021-9673(00)01192-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The elution of ions from a C-18 column with mobile phases containing methanol (60%, v/v) and aqueous buffers is studied by mass spectrometry. It is demonstrated that the anions are excluded from the stationary phase by the ionized silanols. However, the ionized silanols interact strongly with cations, which are retained in the column. These cations are later eluted from the column by ion exchange with the cations present in the pH buffered mobile phase. The size of the ions, the mobile phase cation concentration and the mobile phase pH are the main parameters that affect elution of the retained cations; It is also demonstrated that there are at least two different types of ionizable silanols, with different acidities, that contribute to the retention of cations. An estimate of the pK(a) values of these two groups of silanols in 60% methanol is given. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:187 / 194
页数:8
相关论文
共 20 条
[1]   ON THE DETERMINATION OF THE HOLD-UP TIME IN REVERSED PHASE LIQUID-CHROMATOGRAPHY [J].
BERENDSEN, GE ;
SCHOENMAKERS, PJ ;
GALAN, LD ;
VIGH, G ;
VARGAPUCHONY, Z .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1980, 3 (11) :1669-1686
[2]   Characterization of silica-based octyl phases of different bonding density - Part I. Thermal stability studies [J].
Bereznitski, Y ;
Jaroniec, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :51-58
[3]  
BILDINGMEYER BA, 1982, ANAL CHEM, V54, P442
[4]   Retention of ionizable compounds on high-performance liquid chromatography -: III.: Variation of pK values of acids and pH values of buffers in acetonitrile-water mobile phases [J].
Bosch, E ;
Espinosa, S ;
Rosés, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 824 (02) :137-146
[5]   Retention of ionizable compounds on HPLC. pH scale in methanol-water and the pK and pH values of buffers [J].
Bosch, E ;
Bou, P ;
Allemann, H ;
Roses, M .
ANALYTICAL CHEMISTRY, 1996, 68 (20) :3651-3657
[6]   Retention of ionizable compounds on HPLC.: 4.: Mobile-phase pH measurement in methanol/water [J].
Canals, I ;
Portal, JA ;
Bosch, E ;
Rosés, M .
ANALYTICAL CHEMISTRY, 2000, 72 (08) :1802-1809
[7]  
CANALS I, UNPUB J CHROMATOGR A
[8]   THE INFLUENCE OF SILICA STRUCTURE ON REVERSED-PHASE RETENTION [J].
COX, GB .
JOURNAL OF CHROMATOGRAPHY A, 1993, 656 (1-2) :353-367
[9]   STUDY OF THE RETENTION MECHANISMS FOR BASIC COMPOUNDS ON SILICA UNDER PSEUDO-REVERSED-PHASE CONDITIONS [J].
COX, GB ;
STOUT, RW .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :315-336
[10]   THE CASE OF THE ELUSIVE TM VALUES IN HPLC [J].
DAIGNAULT, LG ;
JACKMAN, DC ;
RILLEMA, DP .
CHROMATOGRAPHIA, 1989, 27 (3-4) :156-158