Non-aqueous enzymology approach for improvement of reagentless mediator-based glucose biosensor

被引:25
作者
Lukachova, LV [1 ]
Karyakin, AA [1 ]
Ivanova, YN [1 ]
Karyakina, EE [1 ]
Varfolomeyev, SD [1 ]
机构
[1] Moscow MV Lomonosov State Univ, Fac Chem, Moscow 119899, Russia
关键词
D O I
10.1039/a803312i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The formation of Nafion membranes containing glucose oxidase and dimethylferrocene as a mediator was optimized using a previously reported non-aqueous enzymology approach for biosensor development. Enzyme immobilization in Nafion membranes was carried out from water-organic mixtures with a high content of organic solvent. The mediator based reagentless glucose electrode was tested in a flow injection system. The response towards glucose addition was stable: the reproducibility during 50 assays exceeded 95%. The response was linear over the glucose concentration range 0.5-50 mM.
引用
收藏
页码:1981 / 1985
页数:5
相关论文
共 18 条
[1]   ENZYMATIC DETERMINATION OF GLUCOSE IN A FLOW SYSTEM BY CATALYTIC-OXIDATION OF THE NICOTINAMIDE COENZYME AT A MODIFIED ELECTRODE [J].
APPELQVIST, R ;
MARKOVARGA, G ;
GORTON, L ;
TORSTENSSON, A ;
JOHANSSON, G .
ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) :237-247
[2]   A REGENERABLE PSEUDO-REAGENTLESS GLUCOSE BIOSENSOR BASED ON NAFION POLYMER AND 1,1'-DIMETHYLFERRICINIUM MEDIATOR [J].
BROWN, RS ;
LUONG, JHT .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :419-427
[3]   A BIOCOMPATIBLE NEEDLE-TYPE GLUCOSE SENSOR BASED ON PLATINUM-ELECTROPLATED CARBON ELECTRODE [J].
CHEN, CY ;
TAMIYA, E ;
ISHIHARA, K ;
KOSUGI, Y ;
SU, YC ;
NAKABAYASHI, N ;
KARUBE, I .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1992, 36 (03) :211-226
[4]   AMPEROMETRIC NEEDLE-TYPE GLUCOSE SENSOR BASED ON A MODIFIED PLATINUM-ELECTRODE WITH DIMINISHED RESPONSE TO INTERFERING MATERIALS [J].
CHEN, CY ;
GOTOH, M ;
MAKINO, H ;
SU, YC ;
TAMIYA, E ;
KARUBE, I .
ANALYTICA CHIMICA ACTA, 1992, 265 (01) :5-14
[5]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[6]  
DONG S, 1991, BIOSENS BIOELECTRON, V7, P215
[7]   OPTIMIZATION OF AMPEROMETRIC MICROSENSORS FOR MONITORING CHOLINE IN THE EXTRACELLULAR FLUID OF BRAIN-TISSUE [J].
GARGUILO, MG ;
MICHAEL, AC .
ANALYTICA CHIMICA ACTA, 1995, 307 (2-3) :291-299
[8]   ENZYME ELECTRODES BASED ON IONOMER FILMS COATED ON ELECTRODES [J].
HARKNESS, JK ;
MURPHY, OJ ;
HITCHENS, GD .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 357 (1-2) :261-272
[9]   Improvement of electrochemical biosensors using enzyme immobilization from water-organic mixtures with a high content of organic solvent [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L ;
Bobrova, OA ;
Lukachova, LV ;
Gladilin, AK ;
Levashov, AV .
ANALYTICAL CHEMISTRY, 1996, 68 (24) :4335-4341
[10]   AN AMPEROMETRIC LACTATE SENSOR EMPLOYING TETRATHIAFULVALENE IN NAFION FILM AS ELECTRON SHUTTLE [J].
LIU, HY ;
DENG, JQ .
ELECTROCHIMICA ACTA, 1995, 40 (12) :1845-1849