Miniaturized dynamic liquid-liquid extraction of organophosphate triesters from blood plasma using the hollow fibre-based XT-tube extractor

被引:13
作者
Jonsson, OB [1 ]
Nilsson, UL [1 ]
机构
[1] Stockholm Univ, Arrhenius Lab, Dept Analyt Chem, S-10691 Stockholm, Sweden
关键词
microporous membrane liquid-liquid extraction hollow fibre; plasma sample clean-up; organophosphate triesters;
D O I
10.1007/s00216-003-2044-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A miniaturized liquid-liquid extractor for bioanalytical sample preparation is described. The extractor consists of a polypropylene hollow fibre mounted inside polytetrafluoroethylene (PTFE) tubing by means of a cross (X) connector and a tee (T) connector. All parts are commercially available, inexpensive, and easily assembled. The aqueous sample, injected into a carrier flow, is pumped along the outside of the fibre and the organic phase, which also wets the pores of the hollow fibre wall, is pumped inside. Eight organophosphate triester (OPE) plasticisers/flame retardants were extracted from 50 muL spiked blood plasma that had been mixed with 50 muL formic acid to denature plasma proteins. The organic phase was a mixture of hexane and methyl tert-butyl ether (MTBE). A high concentration of formic acid in the sample and of MTBE in the organic phase had positive effects on the recovery of some OPE. When investigating the recovery as a function of extraction time it was found that the extraction reached a maximum after 10 min, at a flow-rate of 15 muL min(-1). Recoveries varied between 40 and 80% with RSD around 4% for most compounds. The whole 150-muL extract was injected into a GC-MS system equipped with a programmed-temperature vaporization (PTV) injector. With the MS in selected-ion monitoring (SIM) mode, the LOD for triphenyl phosphate and 2-ethylhexyl diphenyl phosphate were 0.3 and 0.2 ng mL(-1), respectively. More than 40 plasma extractions were performed with the same fibre without any detectable change in extraction efficiency.
引用
收藏
页码:182 / 188
页数:7
相关论文
共 21 条
[1]   ALLERGIC CONTACT-DERMATITIS FROM TRIPHENYL PHOSPHATE [J].
CAMARASA, JG ;
SERRABALDRICH, E .
CONTACT DERMATITIS, 1992, 26 (04) :264-265
[2]   Video display units: An emission source of the contact allergenic flame retardant triphenyl phosphate in the indoor environment [J].
Carlsson, H ;
Nilsson, U ;
Ostman, C .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (18) :3885-3889
[3]   Organophosphate ester flame retardants and plasticizers in the indoor environment: Analytical methodology and occurrence [J].
Carlsson, H ;
Nilsson, U ;
Becker, G ;
Ostman, C .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (10) :2931-2936
[4]  
ERICSSON M, 2003, IN PRESS ANAL CHEM
[5]   Determination of pesticide residues in red wines with microporous membrane liquid-liquid extraction and gas chromatography [J].
Hyötyläinen, T ;
Tuutijärvi, T ;
Kuosmanen, K ;
Riekkola, ML .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (5-6) :732-736
[6]  
Jönsson JÅ, 2001, J SEP SCI, V24, P495, DOI 10.1002/1615-9314(20010801)24:7<495::AID-JSSC495>3.0.CO
[7]  
2-B
[8]   Liquid membrane extraction in analytical sample preparation I.: Principles [J].
Jönsson, JÅ ;
Mathiasson, L .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (05) :318-325
[9]   Membrane-based techniques for sample enrichment [J].
Jönsson, JÅ ;
Mathiasson, L .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (01) :205-225
[10]  
JONSSON OB, 2003, IN PRESS ANAL CHEM