Cannulating in haemodialysis: rope-ladder or buttonhole technique?

被引:118
作者
Verhallen, Annemarie M. [1 ]
Kooistra, Menno P. [1 ]
van Jaarsveld, Brigit C. [1 ]
机构
[1] Dianet Dialysis Ctr, NL-3524 BN Utrecht, Netherlands
关键词
buttonhole technique; cannulation in haemodialysis; rope-ladder technique; self-cannulation; vascular access;
D O I
10.1093/ndt/gfm043
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. The standard technique for fistula cannulation, the rope-ladder technique, is problematic for patients with short fistula lengths and for patients in whom the fistula is difficult to cannulate. The buttonhole technique, cannulation of exactly the same site, offers the advantage of an easy cannulation procedure. However, it can be used only in native fistulas and cannulation is preferably executed by a 'single-sticker'. This study was conducted to compare these cannulation techniques using objective parameters. Methods. We introduced the buttonhole technique for self-cannulating home haemodialysis patients and compared it with baseline data obtained with the rope-ladder technique. Thirty-three patients with a native arteriovenous fistula were observed prospectively during 18 months on the following parameters: cannulating ease, number of bad sticks, pain, time of compression after cannula removal, bleeding, infectious complications and aneurysm formation. Results. With the buttonhole method, cannulating ease improved distinctly, which was especially favourable in patients with a short fistula vein. Reported cannulation pain did not change significantly. The incidence of bad sticks decreased significantly, as well as time of compression after cannula removal, without increased incidence of bleeding. Three patients developed a local skin infection of their buttonhole during the study, after which the disinfection routine prior to cannulation was changed. Conclusions. Compared with the rope-ladder technique, the buttonhole method offers the advantage of an easier cannulation procedure with less bad sticks, which has a special benefit for patients with limited access cannulation sites or with a fistula which is difficult to cannulate. Prolonged compression times or re-bleeding episodes did not occur, but precautions have to be taken in order to prevent infectious complications. The buttonhole method can contribute considerably to the cannulating ease of self-cannulating patients, thus providing a better quality of life.
引用
收藏
页码:2601 / 2604
页数:4
相关论文
共 13 条
[1]  
Ball Lynda K, 2005, Nephrol Nurs J, V32, P611
[2]  
Ball LK, 2006, NEPHROL NURS J, V33, P299
[3]  
BRINKMAN J, 1994, VRANGELIJST, P32
[4]  
*CAS ACC 2006 WORK, 2006, AM J KIDNEY DIS, V48, pS176
[5]  
GOOVAERTS T, 2005, ANN DIAL C TAMP FLOR
[6]  
Harper George, 1997, Home Hemodial Int (1997), V1, P41, DOI 10.1111/hdi.1997.1.1.41
[7]   History of vascular access for haemodialysis [J].
Konner, K .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2005, 20 (12) :2629-2635
[8]  
KRONUNG G, 1984, DIALYSIS TRANSPLANT, V13, P635
[9]  
Marticorena Rosa M, 2006, Hemodial Int, V10, P193, DOI 10.1111/j.1542-4758.2006.00094.x
[10]  
Peterson Patt, 2002, Nephrol Nurs J, V29, P195