Recent advances in biological tissue Imaging with time-of-flight secondary ion mass spectrometry:: Polyatomic ion sources, sample preparation, and applications

被引:43
作者
Brunelle, Alain [1 ]
Laprevote, Olivier [1 ]
机构
[1] CNRS, Inst Chim Subst Nat, Lab Spectrometrie Masse, F-91198 Gif Sur Yvette, France
关键词
review; mass spectrometry; imaging; biological tissue; time-of-flight; secondary ion mass spectrometry; cluster ion source; sample preparation;
D O I
10.2174/138161207782360618
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Recent technological and methodological improvements have greatly enhanced the sensitivity of the Time-of-flight Secondary Ion Mass Spectrometry (TOF-SIMS), thus making this technique now very attractive in the field of molecular imaging of biological samples such as tissue sections or cells. This paper reviews the most recent advances in this field. After a short reminder of the basic physics involved, the instruments are described, as well as the primary ion sources, including the different cluster ion sources. The sample preparation methods are also described and compared, such as the matrix coating and the metal coating. The capabilities of the technique are finally illustrated with the most recent applications published in the last years.
引用
收藏
页码:3335 / 3343
页数:9
相关论文
共 54 条
[1]   Gold-enhanced biomolecular surface imaging of cells and tissue by SIMS and MALDI mass spectrometry [J].
Altelaar, AFM ;
Klinkert, I ;
Jalink, K ;
de Lange, RPJ ;
Adan, RAH ;
Heeren, RMA ;
Piersma, SR .
ANALYTICAL CHEMISTRY, 2006, 78 (03) :734-742
[2]   Direct molecular Imaging of Lymnaea stagnalis nervous tissue at subcellular spatial resolution by mass spectrometry [J].
Altelaar, AFM ;
van Minnen, J ;
Jiménez, CR ;
Heeren, RMA ;
Piersma, SR .
ANALYTICAL CHEMISTRY, 2005, 77 (03) :735-741
[3]   NONLINEAR EFFECTS IN HEAVY-ION SPUTTERING [J].
ANDERSEN, HH ;
BAY, HL .
JOURNAL OF APPLIED PHYSICS, 1974, 45 (02) :953-954
[4]  
[Anonymous], 1997, TIME FLIGHT MASS SPE
[5]   COMPARISON OF POLYATOMIC AND ATOMIC PRIMARY BEAMS FOR SECONDARY ION MASS-SPECTROMETRY OF ORGANICS [J].
APPELHANS, AD ;
DELMORE, JE .
ANALYTICAL CHEMISTRY, 1989, 61 (10) :1087-1093
[6]   Time-of-flight secondary ion mass spectrometry: techniques and applications for the characterization of biomaterial surfaces [J].
Belu, AM ;
Graham, DJ ;
Castner, DG .
BIOMATERIALS, 2003, 24 (21) :3635-3653
[7]   IMPACT OF SLOW GOLD CLUSTERS ON VARIOUS SOLIDS - NONLINEAR EFFECTS IN SECONDARY ION EMISSION [J].
BENGUERBA, M ;
BRUNELLE, A ;
DELLANEGRA, S ;
DEPAUW, J ;
JORET, H ;
LEBEYEC, Y ;
BLAIN, MG ;
SCHWEIKERT, EA ;
BENASSAYAG, G ;
SUDRAUD, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 62 (01) :8-22
[8]   SURFACE MS - PROBING REAL-WORLD SAMPLES [J].
BENNINGHOVEN, A ;
HAGENHOFF, B ;
NIEHUIS, E .
ANALYTICAL CHEMISTRY, 1993, 65 (14) :A630-A640
[9]   ORGANIC FILM THICKNESS EFFECT IN SECONDARY ION MASS-SPECTROMETRY AND PLASMA DESORPTION MASS-SPECTROMETRY [J].
BOLBACH, G ;
VIARI, A ;
GALERA, R ;
BRUNOT, A ;
BLAIS, JC .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 112 (01) :93-100
[10]   SECONDARY-ION EMISSION UNDER CLUSTER-IMPACT AT LOW ENERGIES (5-60 KEV) - INFLUENCE OF THE NUMBER OF ATOMS IN THE PROJECTILE [J].
BOUSSOFIANEBAUDIN, K ;
BOLBACH, G ;
BRUNELLE, A ;
DELLANEGRA, S ;
HAKANSSON, P ;
LEBEYEC, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 88 (1-2) :160-163