Multiphoton excitation provides optical sections from deeper within scattering specimens than confocal imaging

被引:383
作者
Centonze, VE
White, JG
机构
[1] Univ Wisconsin, Integrated Microscopy Resource, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Anat, Mol Biol Lab, Madison, WI 53706 USA
关键词
D O I
10.1016/S0006-3495(98)77643-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Multiphoton excitation fluorescence imaging generates an optical section of sample by restricting fluorophore excitation to the plane of focus. High photon densities, achieved only in the focal Volume of the objective, are sufficient to excite the fluorescent probe molecules by density-dependent, multiphoton excitation processes. We present comparisons of confocal with multiphoton excitation imaging of identical optical sections within a sample. These side-by-side comparisons of imaging modes demonstrate a significant advantage of multiphoton imaging; data can be obtained from deeper within biological specimens. Observations on a variety of biological samples showed that in all cases there was at least a twofold improvement in the imaging penetration depth obtained with multiphoton excitation relative to confocal imaging. The more pronounced degradation in image contrast deep within a confocally imaged sample is primarily due to scattered emission photons, which reduce the signal and increase the local background as measurements of point spread functions indicated that resolution does not significantly change with increasing depth for either mode of microscopy. Multiphoton imaging does not suffer from degradation of signal-to-background to nearly the same extent as confocal imaging because this method is insensitive to scatter of the emitted signal. Direct detection of emitted photons using an external photodetector mounted close to the objective (possible only in a multiphoton imaging system) improves system sensitivity and the utilization of scattered emission photons for imaging. We demonstrate that this technique provides yet further improvements in the capability of multiphoton excitation imaging to produce good quality images from deeper within tissue relative to confocal imaging.
引用
收藏
页码:2015 / 2024
页数:10
相关论文
共 29 条
  • [1] Bhawalkar J. D., 1996, Bioimaging, V4, P168, DOI 10.1002/1361-6374(199609)4:3<168::AID-BIO7>3.3.CO
  • [2] 2-#
  • [3] 3-DIMENSIONAL CHROMATIN DISTRIBUTION IN NEURO-BLASTOMA NUCLEI SHOWN BY CONFOCAL SCANNING LASER MICROSCOPY
    BRAKENHOFF, GJ
    VANDERVOORT, HTM
    VANSPRONSEN, EA
    LINNEMANS, WAM
    NANNINGA, N
    [J]. NATURE, 1985, 317 (6039) : 748 - 749
  • [4] BRENNER M, 1994, AM LAB APR, P14
  • [5] Centonze Victoria, 1995, P549
  • [6] 2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY
    DENK, W
    STRICKLER, JH
    WEBB, WW
    [J]. SCIENCE, 1990, 248 (4951) : 73 - 76
  • [7] ANATOMICAL AND FUNCTIONAL IMAGING OF NEURONS USING 2-PHOTON LASER-SCANNING MICROSCOPY
    DENK, W
    DELANEY, KR
    GELPERIN, A
    KLEINFELD, D
    STROWBRIDGE, BW
    TANK, DW
    YUSTE, R
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 1994, 54 (02) : 151 - 162
  • [8] 2 TYPES OF CALCIUM RESPONSE LIMITED TO SINGLE SPINES IN CEREBELLAR PURKINJE-CELLS
    DENK, W
    SUGIMORI, M
    LLINAS, R
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (18) : 8279 - 8282
  • [9] Photon upmanship: Why multiphoton imaging is more than a gimmick
    Denk, W
    Svoboda, K
    [J]. NEURON, 1997, 18 (03) : 351 - 357
  • [10] Denk W, 1996, J Biomed Opt, V1, P296, DOI 10.1117/12.242945