Preload dependence of new Doppler techniques limits their utility for left ventricular diastolic function assessment in hemodialysis patients

被引:64
作者
Ie, EHY
Vletter, WB
Ten Cate, FJ
Nette, RW
Weimar, W
Roelandt, JRTC
Zietse, R
机构
[1] Erasmus MC, Dept Med, NL-3015 GD Rotterdam, Netherlands
[2] Erasmus MC, Dept Cardiol, NL-3015 GD Rotterdam, Netherlands
来源
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY | 2003年 / 14卷 / 07期
关键词
D O I
10.1097/01.ASN.0000072745.94551.FC
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Left ventricular (LV) hypertrophy leads to diastolic dysfunction. Standard Doppler transmitral and pulmonary vein (PV) flow velocity measurements are preload dependent. New techniques such as mitral annulus velocity by Doppler tissue imaging (DTI) and LV inflow propagation velocity measured from color M-mode have been proposed as relatively preload-independent measurements of diastolic function. These parameters were studied before and after hemodialysis (HD) with ultrafiltration to test their potential advantage for LV diastolic function assessment in HD patients. Ten patients (seven with LV hypertrophy) underwent Doppler echocardiography I h before, I h after, and 1 d after HD. Early (E) and atrial (A) peak transmitral flow velocities, peak PV systolic (s) and diastolic (d) flow velocities, peak e and a mitral annulus velocities in DTI, and early diastolic LV flow propagation velocity (V-p) were measured. In all patients, the E/A ratio after HD (0.54; 0.37 to 1.02) was lower (P < 0.01) than before HD (0.77; 0.60 to 1.34). E decreased (P < 0.01), whereas A did not. PV s/d after HD (2.15; 1.08 to 3.90) was higher (P < 0.01) than before HD (1.80; 1.25 to 2.68). Tissue e/a after HD (0.40; 0.26 to 0.96) was lower (P < 0.01) than before HD (0.56; 0.40 to 1.05). Tissue e decreased (P < 0.02), whereas a did not. V-P after HD (30 cm/s; 16 to 47 cm/s) was lower (P < 0.01) than before HD (45 cm/s; 32 to 60 cm/s). Twenty-four hours after the initial measurements values for E/A (0.59; 0.37 to 1.23), PV s/d (1.85; 1.07 to 3.38), e/a (0.41; 0.27 to 1.06), and VP (28 cm/s; 23 to 33 cm/s) were similar as those taken 1 h after HD. It is concluded that, even when using the newer Doppler techniques DTI and color M-mode, pseudonormalization, which was due to volume overload before HD, resulted in underestimation of the degree of diastolic dysfunction. Therefore, the advantage of these techniques over conventional parameters for the assessment of LV diastolic function in HD patients is limited. Assessment of LV diastolic function should not be performed shortly before HD, and its time relation to HD is essential.
引用
收藏
页码:1858 / 1862
页数:5
相关论文
共 27 条
  • [1] ASSESSMENT OF THE CARDIAC EFFECTS OF HEMODIALYSIS WITH SYSTOLIC-TIME INTERVALS AND ECHOCARDIOGRAPHY
    BORNSTEIN, A
    GAASCH, WH
    HARRINGTON, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1983, 51 (02) : 332 - 335
  • [2] Color M-mode flow propagation velocity versus conventional Doppler indices in the assessment of diastolic left ventricular function in patients on chronic hemodialysis
    Chamoun, AJ
    Xie, TR
    Trough, M
    Esquivel-Avila, J
    Carson, R
    DeFilippi, C
    Ahmad, M
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2002, 19 (06): : 467 - 474
  • [3] CHERIEX EC, 1989, NEPHROL DIAL TRANSPL, V4, P563
  • [4] PRELOAD DEPENDENCE OF DOPPLER-DERIVED INDEXES OF LEFT-VENTRICULAR DIASTOLIC FUNCTION IN HUMANS
    CHOONG, CY
    HERRMANN, HC
    WEYMAN, AE
    FIFER, MA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) : 800 - 808
  • [5] DIALYSIS HYPOTENSION - A HEMODYNAMIC ANALYSIS
    DAUGIRDAS, JT
    [J]. KIDNEY INTERNATIONAL, 1991, 39 (02) : 233 - 246
  • [6] Pathophysiology of dialysis hypotension: An update
    Daugirdas, JT
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2001, 38 (04) : S11 - S17
  • [7] ECHOCARDIOGRAPHIC DETERMINATION OF LEFT-VENTRICULAR MASS IN MAN - ANATOMIC VALIDATION OF METHOD
    DEVEREUX, RB
    REICHEK, N
    [J]. CIRCULATION, 1977, 55 (04) : 613 - 618
  • [8] New Doppler echocardiographic applications for the study of diastolic function
    Garcia, MJ
    Thomas, JD
    Klein, AL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (04) : 865 - 875
  • [9] An index of early left ventricular filling that combined with pulsed Doppler peak E velocity may estimate capillary wedge pressure
    Garcia, MJ
    Ares, MA
    Asher, C
    Rodriguez, L
    Vandervoort, P
    Thomas, JD
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 448 - 454
  • [10] GILMARTIN JJ, 1983, CLIN NEPHROL, V20, P55