Milestones in Fourier transform ion cyclotron resonance mass spectrometry technique development

被引:236
作者
Marshall, AG [1 ]
机构
[1] Florida State Univ, Natl High Magnet Field Lab, Ctr Interdisciplinary Magnet Resonance, Tallahassee, FL 32310 USA
[2] Florida State Univ, Dept Chem, Tallahassee, FL 32306 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
ICR; FTICR; FTMS; dissociation; fragmentation; excitation; detection; penning trap; ion trap;
D O I
10.1016/S1387-3806(00)00324-9
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The present range and power of Fourier transform ion cyclotron resonance mass spectrometry rest on a number of prior technique developments. In this article, selected developments in neutral/ion introduction, ionization methods, excitation/detection, ion trap configuration/operating modes, ion dissociation and MS/MS, ion cooling techniques, theory and data reduction are briefly explained and chronicled. Evidence for the value of these techniques is provided by a compilation of current world records for mass resolution, mass resolving power and mass accuracy. With these capabilities, it becomes possible to resolve and identify up to thousands of components of a complex mixture, often without prior wet chemical separation, thereby potentially changing the whole approach to dealing with chemical and biological complexity. (C) 2000 Elsevier Science B.V.
引用
收藏
页码:331 / 356
页数:26
相关论文
共 287 条
[11]   OPEN TRAPPED ION CELL GEOMETRIES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 112 (2-3) :215-230
[12]   ELIMINATION OF AXIAL EJECTION DURING EXCITATION WITH A CAPACITIVELY COUPLED OPEN TRAPPED-ION CELL FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
BEU, SC ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :177-180
[13]   IMPROVED FOURIER-TRANSFORM ION-CYCLOTRON-RESONANCE MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (02) :190-192
[14]   LINE-NARROWING BY MACROSCOPIC MOTION [J].
BLOCH, F .
PHYSICAL REVIEW, 1954, 94 (02) :496-497
[15]   LOW-ENERGY COLLISION-INDUCED DISSOCIATION - PHASE-SHIFTING EXCITATION CONTROL OF ION KINETIC-ENERGY IN ION-CYCLOTRON RESONANCE SPECTROMETRY [J].
BOERING, KA ;
ROLFE, J ;
BRAUMAN, JI .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 117 (1-3) :357-386
[16]   THE ACCURACY OF HEAVY-ION MASS MEASUREMENTS USING TIME OF FLIGHT-ION CYCLOTRON-RESONANCE IN A PENNING TRAP [J].
BOLLEN, G ;
MOORE, RB ;
SAVARD, G ;
STOLZENBERG, H .
JOURNAL OF APPLIED PHYSICS, 1990, 68 (09) :4355-4374
[17]   FRAGMENTATION OF OLIGOPEPTIDE IONS USING ULTRAVIOLET-LASER RADIATION AND FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
BOWERS, WD ;
DELBERT, SS ;
HUNTER, RL ;
MCIVER, RT .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1984, 106 (23) :7288-7289
[18]   GEONIUM THEORY - PHYSICS OF A SINGLE ELECTRON OR ION IN A PENNING TRAP [J].
BROWN, LS ;
GABRIELSE, G .
REVIEWS OF MODERN PHYSICS, 1986, 58 (01) :233-311
[19]   Obtaining more accurate Fourier transform ion cyclotron resonance mass measurements without internal standards using multiply charged ions [J].
Bruce, JE ;
Anderson, GA ;
Brands, MD ;
Pasa-Tolic, L ;
Smith, RD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (05) :416-421
[20]   THE INFINITY CELL - A NEW TRAPPED-ION CELL WITH RADIOFREQUENCY COVERED TRAPPING ELECTRODES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
CARAVATTI, P ;
ALLEMANN, M .
ORGANIC MASS SPECTROMETRY, 1991, 26 (05) :514-518