Milestones in Fourier transform ion cyclotron resonance mass spectrometry technique development

被引:236
作者
Marshall, AG [1 ]
机构
[1] Florida State Univ, Natl High Magnet Field Lab, Ctr Interdisciplinary Magnet Resonance, Tallahassee, FL 32310 USA
[2] Florida State Univ, Dept Chem, Tallahassee, FL 32306 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
ICR; FTICR; FTMS; dissociation; fragmentation; excitation; detection; penning trap; ion trap;
D O I
10.1016/S1387-3806(00)00324-9
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The present range and power of Fourier transform ion cyclotron resonance mass spectrometry rest on a number of prior technique developments. In this article, selected developments in neutral/ion introduction, ionization methods, excitation/detection, ion trap configuration/operating modes, ion dissociation and MS/MS, ion cooling techniques, theory and data reduction are briefly explained and chronicled. Evidence for the value of these techniques is provided by a compilation of current world records for mass resolution, mass resolving power and mass accuracy. With these capabilities, it becomes possible to resolve and identify up to thousands of components of a complex mixture, often without prior wet chemical separation, thereby potentially changing the whole approach to dealing with chemical and biological complexity. (C) 2000 Elsevier Science B.V.
引用
收藏
页码:331 / 356
页数:26
相关论文
共 287 条
[81]   THEORY OF HIGH-RESOLUTION MASS-SPECTROMETRY ACHIEVED VIA RESONANCE EJECTION IN THE QUADRUPOLE ION TRAP [J].
GOERINGER, DE ;
WHITTEN, WB ;
RAMSEY, JM ;
MCLUCKEY, SA ;
GLISH, GL .
ANALYTICAL CHEMISTRY, 1992, 64 (13) :1434-1439
[82]   MASSES OF STABLE NEON ISOTOPES DETERMINED AT PARTS-PER-BILLION PRECISION BY FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
GORSHKOV, MV ;
GUAN, SH ;
MARSHALL, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 128 (1-2) :47-60
[83]   DYNAMIC ION TRAPPING FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY - SIMULTANEOUS POSITIVE-ION AND NEGATIVE-ION DETECTION [J].
GORSHKOV, MV ;
GUAN, SH ;
MARSHALL, AG .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (03) :166-172
[84]   Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry at 11.5 tesla: Instrument design and initial results [J].
Gorshkov, MV ;
Tolic, LP ;
Udseth, HR ;
Anderson, GA ;
Huang, BM ;
Bruce, JE ;
Prior, DC ;
Hofstadler, SA ;
Tang, LA ;
Chen, LZ ;
Willett, JA ;
Rockwood, AL ;
Sherman, MS ;
Smith, RD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (07) :692-700
[86]   FOURIER-TRANSFORM MASS-SPECTROMETRY [J].
GROSS, ML ;
REMPEL, DL .
SCIENCE, 1984, 226 (4672) :261-268
[87]   COMPREHENSIVE THEORY OF THE FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SIGNAL FOR ALL ION TRAP GEOMETRIES [J].
GROSSHANS, PB ;
SHIELDS, PJ ;
MARSHALL, AG .
JOURNAL OF CHEMICAL PHYSICS, 1991, 94 (08) :5341-5352
[88]   THEORY OF ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY - RESONANT EXCITATION AND RADIAL EJECTION IN ORTHORHOMBIC AND CYLINDRICAL ION TRAPS [J].
GROSSHANS, PB ;
MARSHALL, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 100 :347-379
[89]   CAN FOURIER-TRANSFORM MASS-SPECTRAL RESOLUTION BE IMPROVED BY DETECTION AT HARMONIC MULTIPLES OF THE FUNDAMENTAL ION-CYCLOTRON ORBITAL FREQUENCY [J].
GROSSHANS, PB ;
MARSHALL, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 107 (01) :49-81
[90]   GENERAL-THEORY OF EXCITATION IN ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY [J].
GROSSHANS, PB ;
MARSHALL, AG .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2057-2061