Comparison of selective procedures for isolation and enumeration of Legionella species from hot water systems

被引:94
作者
Leoni, E [1 ]
Legnani, PP [1 ]
机构
[1] Univ Bologna, Dipartimento Med & Sanita Pubbl, I-40126 Bologna, Italy
关键词
D O I
10.1046/j.1365-2672.2001.01178.x
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Various sample pre-treatment techniques and different growth media for the isolation of Legionellae from hot water supplies in public buildings were compared. A total of 102 hot water samples from taps and showers was examined, The highest recovery frequency was obtained with the heat pre-treatment method and using the selective medium GVPC, However, the results differed according to the concentration of legionellas. In the case of low plate counts (less than or equal to 5000 cfu l(-1)), the heat pre-treatment technique gave a significantly higher percentage of positive samples compared with other techniques (P < 0.05). With increasing concentration, the differences between the procedures decreased until they became statistically not significant for concentrations above 50 000 cfu l(-1). The direct inoculum method allowed a significantly higher detection of concentrations (P < 0.001) compared with heat and acid decontamination methods, which brought about a 67-68% reduction in detectable Legionellae. Heat decontamination techniques show greater sensitivity and specificity. However, they underestimate the number of legionellas, In environmental surveillance programmes, this underestimate must be taken into consideration when assessing the health risk.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 29 条
[1]  
[Anonymous], 1998, 11731 ISO
[2]   DETECTION OF VIABLE LEGIONELLA-PNEUMOPHILA IN WATER BY POLYMERASE CHAIN-REACTION AND GENE PROBE METHODS [J].
BEJ, AK ;
MAHBUBANI, MH ;
ATLAS, RM .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1991, 57 (02) :597-600
[3]   PRECISION AND ACCURACY OF RECOVERY OF LEGIONELLA-PNEUMOPHILA FROM SEEDED TAP WATER BY FILTRATION AND CENTRIFUGATION [J].
BOULANGER, CA ;
EDELSTEIN, PH .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1995, 61 (05) :1805-1809
[4]   LEGIONELLA-PNEUMOPHILA - COMPARISON OF ISOLATION FROM WATER SPECIMENS BY CENTRIFUGATION AND FILTRATION [J].
BRINDLE, RJ ;
STANNETT, PJ ;
CUNLIFFE, RN .
EPIDEMIOLOGY AND INFECTION, 1987, 99 (02) :241-247
[5]  
De Luca G, 1999, MICROBIOLOGICA, V22, P203
[6]   COMPARATIVE-STUDY OF SELECTIVE MEDIA FOR ISOLATION OF LEGIONELLA-PNEUMOPHILA FROM POTABLE WATER [J].
EDELSTEIN, PH .
JOURNAL OF CLINICAL MICROBIOLOGY, 1982, 16 (04) :697-699
[7]  
GOMEZLUS R, 1993, LEGIONELLA, P265
[8]   INFLUENCE OF TEMPERATURE ON THE NUMBER OF LEGIONELLA-PNEUMOPHILA IN HOT WATER-SYSTEMS [J].
GROOTHUIS, DG ;
VEENENDAAL, HR ;
DIJKSTRA, HL .
JOURNAL OF APPLIED BACTERIOLOGY, 1985, 59 (06) :529-536
[9]  
Harrison TG, 1988, LAB MANUAL LEGIONELL, V1st
[10]   ISOLATION OF LEGIONELLA SPECIES FROM DRINKING-WATER [J].
HSU, SC ;
MARTIN, R ;
WENTWORTH, BB .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1984, 48 (04) :830-832