Wearable and flexible oxygen sensor for transcutaneous oxygen monitoring

被引:50
作者
Mitsubayashi, K
Wakabayashi, Y
Murotomi, D
Yamada, T
Kawase, T
Iwagaki, S
Karube, I
机构
[1] Tokai Univ, Dept Human & Informat Sci, Hiratsuka, Kanagawa 2591292, Japan
[2] Tokai Univ, Sch Phys Educ, Dept Phys Recreat, Hiratsuka, Kanagawa 2591292, Japan
[3] Tokyo Univ Technol, Katayanagi Adv Res Labs, Hachioji, Tokyo 1920982, Japan
关键词
wearable oxygen sensor; transcutaneous oxygen monitoring; gas-permeable membrane; metal weldable membrane;
D O I
10.1016/S0925-4005(03)00441-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A wearable and flexible oxygen sensor with membrane structure was constructed by pouching KCl electrolyte solution by both non-permeable (metal weldable) sheet and gas-permeable membrane with Pt- and Ag/AgCl-electrode patterned by microfabrication techniques. The electrolyte solution was fastened only by heat-sealing the edges of the weldable membranes without any chemical adhesives. The wearable oxygen sensor (thickness: 84 mum) was applied to the electrochemical measurement with a fixed potential of -600 mV vs. Ag/AgCl, thus obtaining the calibration range to dissolved oxygen (DO) from 0 to 8.0 mg/l and the quick response time (I I s to 90% of a steady-state current), which operate similarly to a commercially available oxygen electrode. By placing the wearable oxygen sensor onto the forearm skin surface of the subject inhaling various concentrations of oxygen the gas phase as the physiological application of it, the transcutaneous oxygen pressure was successfully monitored without any inconveniences such as skin inflammation, etc. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:373 / 377
页数:5
相关论文
共 14 条
  • [1] CLARK LC, 1956, T AM SOC ART INT ORG, V2, P41
  • [2] DUE G, 1975, PEDIATRICS, V55, P55
  • [3] OXYGEN TENSION GRADIENT ACROSS HUMAN EPIDERMIS
    EVANS, NTS
    NAYLOR, PFD
    [J]. RESPIRATION PHYSIOLOGY, 1967, 3 (01): : 38 - &
  • [4] Hagihara B., 1984, JPN J CLIN PATHOL, V32, P1065
  • [5] RELIABILITY OF TRANSCUTANEOUS MONITORING OF ARTERIAL PO2 IN NEWBORN-INFANTS
    HUCH, R
    LUBBERS, DW
    HUCH, A
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1974, 49 (03) : 213 - 218
  • [6] Huch R, 1973, J Perinat Med, V1, P183, DOI 10.1515/jpme.1973.1.3.183
  • [7] IMURA S, 1975, CIRCULATION, V23, P53
  • [8] BLOODLESS, CONTINUOUS MONITORING OF ACID/BASE STATUS IN MANN BY TRANSCUTANEOUS MEASUREMENTS OF ARTERIAL PO2 AND PCO2 AS WELL AS CONCENTRATION OF HEMOGLOBIN AT BODY-TEMPERATURE
    LUBBERS, DW
    HUCH, A
    HUCH, R
    [J]. KLINISCHE WOCHENSCHRIFT, 1973, 51 (08): : 411 - 412
  • [9] GAS-PHASE BIOSENSOR FOR ETHANOL
    MITSUBAYASHI, K
    YOKOYAMA, K
    TAKEUCHI, T
    KARUBE, I
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (20) : 3297 - 3302
  • [10] FLEXIBLE CONDUCTIMETRIC SENSOR
    MITSUBAYASHI, K
    YOKOYAMA, K
    TAKEUCHI, T
    TAMIYA, E
    KARUBE, I
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (24) : 3586 - 3590