Data continuity of Earth Observing 1 (EO-1) Advanced Land Imager (ALI) and Landsat TM and ETM

被引:30
作者
Bryant, R [1 ]
Moran, MS
McElroy, SA
Holifield, C
Thome, KJ
Miura, T
Biggar, SF
机构
[1] USDA, ARS, SW Watershed Res Ctr, Tucson, AZ 85719 USA
[2] Univ Arizona, Ctr Opt Sci, Tucson, AZ 85721 USA
[3] Univ Arizona, Dept Soil Water & Environm Sci, Tucson, AZ 85721 USA
来源
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING | 2003年 / 41卷 / 06期
基金
美国国家航空航天局;
关键词
Advanced Land Imager (ALI); data continuity; Earth Observing 1 (EO-1); Landsat Thematic Mapper 4 (TM4); Landsat Thematic Mapper 5 (TM5); Landsat Enhanced Thematic Mapper Plus (ETM plus ); remote sensing;
D O I
10.1109/TGRS.2003.813213
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The National Aeronautics and Space Administration (NASA) Landsat program has been dedicated to sustaining data continuity over the 20-year period during which Landsat Thematic Mapper (TM) and Enhanced TM Plus (ETM+) sensors have been acquiring images of the earth's surface. In 2000, NASA launched the, Earth Observing-1 (EO-1) Advanced Land Imager (ALI) to test new technology that could improve the TM/ETM+ sensor series, yet ensure Landsat data continuity. The study reported here quantified the continuity of satellite-retrieved surface reflectance (p) for the three most recent Landsat sensors (Landsat-4 TM, Landsat-5 TM, and Landsat-7 ETM+) and the EO-1 ALI sensor. The study was based on ground-data verification and, in the case of the ETM+ to ALI comparison, coincident image analysis. Reflectance retrieved from all four sensors showed good correlation with ground-measured reflectance, and the sensor-to-sensor data continuity was excellent for all sensors and all bands. A qualitative analysis of the new ALI spectral bands (4p: 0.845-0.890 mum and 5p: 1.20-1.30 mum) showed that ALI band 5p provided information that was different from that provided by the ETM+/ALI shortwave infrared bands 5 and 7 for agricultural targets and that ALI hand 4p has the advantage over the existing ETM+ near-infrared (NIR) band 4 and ALI NIR band 4 of being relatively insensitive to water vapor absorption. The basic conclusion of this study is that the four sensors can provide excellent data continuity for temporal studies of natural resources. Furthermore, the new technologies put forward by the EO-1 ALI sensor have had no apparent effect on data continuity and should be considered for the upcoming Landsat-8 sensor payload.
引用
收藏
页码:1204 / 1214
页数:11
相关论文
共 11 条
[1]   IMPROVED EVALUATION OF OPTICAL DEPTH COMPONENTS FROM LANGLEY PLOT DATA [J].
BIGGAR, SF ;
GELLMAN, DI ;
SLATER, PN .
REMOTE SENSING OF ENVIRONMENT, 1990, 32 (2-3) :91-101
[2]  
IRONS JV, COMMUNICATION
[3]  
LENCIONI DE, 1999, P SPIE C SENS SYST N, V3
[4]  
METZLER MD, 1985, PHOTOGRAMM ENG REM S, V51, P1315
[5]   A refined empirical line approach for reflectance factor retrieval from Landsat-5 TM and Landsat-7 ETM+ [J].
Moran, MS ;
Bryant, R ;
Thome, K ;
Ni, W ;
Nouvellon, Y ;
Gonzalez-Dugo, MP ;
Qi, J .
REMOTE SENSING OF ENVIRONMENT, 2001, 78 (1-2) :71-82
[6]   EVALUATING COTTON RESPONSE TO FREE-AIR CARBON-DIOXIDE ENRICHMENT WITH CANOPY REFLECTANCE OBSERVATIONS [J].
PINTER, PJ ;
ANDERSON, RJ ;
KIMBALL, BA ;
MAUNEY, JR .
CRITICAL REVIEWS IN PLANT SCIENCES, 1992, 11 (2-3) :241-249
[7]   CALIBRATION COMPARISON FOR THE LANDSAT-4 AND LANDSAT-5 MULTISPECTRAL SCANNERS AND THEMATIC MAPPERS [J].
PRICE, JC .
APPLIED OPTICS, 1989, 28 (03) :465-471
[8]  
Renard K. G., 1993, hydrological science and technology, V9, P145
[9]   Absolute radiometric calibration of Landsat 7 ETM+ using the reflectance-based method [J].
Thome, KJ .
REMOTE SENSING OF ENVIRONMENT, 2001, 78 (1-2) :27-38
[10]   Effects of landsat 5 thematic mapper and Landsat 7 enhanced thematic mapper plus radiometric and geometric calibrations and corrections on landscape characterization [J].
Vogelmann, JE ;
Helder, D ;
Morfitt, R ;
Choate, MJ ;
Merchant, JW ;
Bulley, H .
REMOTE SENSING OF ENVIRONMENT, 2001, 78 (1-2) :55-70