Reduction of silanophilic interactions in liquid chromatography with the use of ionic liquids

被引:88
作者
Marszall, MP [1 ]
Baczek, T [1 ]
Kaliszan, R [1 ]
机构
[1] Med Univ Gdansk, Dept Biopharmaceut & Pharmacodynam, PL-80416 Gdansk, Poland
关键词
ionic liquids; liquid chromatography; suppression of silanophilic interactions;
D O I
10.1016/j.aca.2005.05.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A suppression of silanophilic interactions by the selected ionic liquids added to the mobile phase in thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC) is reported. Acetonitrile was used as the cluent, alone or with various concentrations of water and phosphoric buffer pH 3. Selectivity of the normal (NP) and the reversed (RP) stationary phase material was examined using a series of proton-acceptor basic drugs analytes. The ionic liquids studied appeared to significantly affect analyte retention in NP-TLC, RP-TLC and RP-HPLC systems tested. Consequently, the increased separation selectivity was attained. Due to ionic liquid additives to eluent even analytes could be chromatographed, which were not eluted from the silica-based stationary phase materials with 100% of acetonitrile in the mobile phase. Addition of ionic liquid already in very small concentration (0.5%, v/v) could reduce the amount of acetonitrile used during the optimization of basic analytes separations in TLC and HPLC systems. Moreover, the influence of temperature on the separation of basic analytes was demonstrated and considered in practical HPLC method development. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:172 / 178
页数:7
相关论文
共 26 条
[1]   Examination of ionic liquids and their interaction with molecules, when used as stationary phases in gas chromatography [J].
Armstrong, DW ;
He, LF ;
Liu, YS .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3873-3876
[2]   Use of the ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate in countercurrent chromatography [J].
Berthod, A ;
Carda-Broch, S .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (01) :168-177
[3]  
Bertoni A. De W., 1904, Anales Cient Parag, VSer. I, P1
[4]   Effect of mobile phase additives on peptide retention in reversed-phase chromatography with pellicular and totally porous sorbents [J].
Corradini, D ;
Kalghatgi, K ;
Horvath, C .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :225-233
[5]   BARE SILICA, DYNAMICALLY MODIFIED WITH LONG-CHAIN QUATERNARY AMMONIUM-IONS - THE TECHNIQUE OF CHOICE FOR MORE REPRODUCIBLE SELECTIVITY IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HANSEN, SH ;
HELBOE, P ;
THOMSEN, M .
JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2) :53-76
[6]   COLUMN LIQUID-CHROMATOGRAPHY ON DYNAMICALLY MODIFIED SILICA .1. [J].
HANSEN, SH .
JOURNAL OF CHROMATOGRAPHY, 1981, 209 (02) :203-210
[7]   Effect of 1-alkyl-3-methylimidazolium-based ionic liquids as the eluent on the separation of ephedrines by liquid chromatography [J].
He, LJ ;
Zhang, WZ ;
Zhao, L ;
Liu, X ;
Jiang, SX .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1007 (1-2) :39-45
[8]   Thermodynamic properties of mixtures containing ionic liquids.: 1.: Activity coefficients at infinite dilution of alkanes, alkenes, and alkylbenzenes in 4-methyl-n-butylpyridinium tetrafluoroborate using gas-liquid chromatography [J].
Heintz, A ;
Kulikov, DV ;
Verevkin, SP .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2001, 46 (06) :1526-1529
[9]  
HELBOE P, 1989, ADV CHROMATOGR, V28, P195
[10]   Suppression of deleterious effects of free silanols in liquid chromatography by imidazolium tetrafluoroborate ionic liquids [J].
Kaliszan, R ;
Marszall, MP ;
Markuszewski, MJ ;
Baczek, T ;
Pernak, J .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1030 (1-2) :263-271