Multifocal electroretinography (MF-ERG) in age-related macular degeneration

被引:34
作者
Palmowski, AM [1 ]
Sutter, EE
Bearse, MA
Fung, W
机构
[1] Univ Saarlandes, Augenklin & Poliklin, D-66421 Homburg, Germany
[2] Smith Kettlewell Eye Res Inst, San Francisco, CA 94115 USA
[3] Calif Med Ctr, San Francisco, CA USA
来源
OPHTHALMOLOGE | 1999年 / 96卷 / 03期
关键词
multifocal electroretinogram; age-related macular degeneration; follow-up; noninvasive electroretinogram; retina;
D O I
10.1007/s003470050389
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Smalt areas of retinal pathology may pose diagnostic difficulties. The noninvasive multifocal electroretinogram (MF-ERG) provides a topographical mapping of retinal function. Its role in the diagnosis of macular diseases is examined in age-related macular degeneration (AMD). AMD is a main cause of central visual loss in the elderly population, affecting the second eye in 75 %. Methods: MF-ERG recordings of three patients with AMD were compared to the findings of fundus photography and fluorescein angiography. During the MF-ERG recordings the central 50 degrees of the retina was stimulated. The Visual stimulus consisted of 241 hexagons that alternated,independently and pseudorandomly, between black and white according to a special predetermined binary sequence. local retinal response components were extracted using the Fast m-Transform Algorithm. Results: Three of six eyes had undergone cataract surgery with implantation of a posterior chamber lens (PCL). In accordance with an increase in light transmission through PCLs, these eyes showed an increase in the MF-ERG responses. MF-ERG allowed accurate topographic mapping of focal areas of retinal dysfunction in all patients tested. There was good correspondence to anatomical changes detected by fluorescein angiography. Conclusion: The high resolution of the MF-ERG enables detection of small areas of retinal pathology. It thus presents a clinically useful, noninvasive method in the early diagnosis and follow-up of macular disease.
引用
收藏
页码:166 / 173
页数:8
相关论文
共 18 条
[1]  
Bearse MA, 1996, J OPT SOC AM A, V13, P634, DOI 10.1364/JOSAA.13.000634
[2]  
BEARSE MA, 1994, VISION SCI ITS APPL, V2, P358
[3]  
BEARSE MA, 1995, OSA TECHNICAL DIGEST, V1, P310
[4]  
BIERSDORF WR, 1990, DOC OPHTHALMOL, V73, P313
[5]  
Brown B, 1996, OPHTHAL PHYSL OPT, V16, P42, DOI 10.1016/0275-5408(95)00043-7
[6]   Fundus reflectance and the measurement of crystalline lens density [J].
Delori, FC ;
Burns, SA .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1996, 13 (02) :215-226
[7]  
GROUP MPS, 1994, ARCH OPHTHALMOL-CHIC, V112, P500
[8]  
HOOD DC, 1998, IN PRESS VIS NEUROSC
[9]  
KONDO M, 1995, INVEST OPHTH VIS SCI, V36, P2146
[10]  
Palmowski AM, 1997, INVEST OPHTH VIS SCI, V38, P2586