COST 732 in practice: the MUST model evaluation exercise

被引:67
作者
Di Sabatino, Silvana [1 ]
Buccolieri, Riccardo [1 ,2 ]
Olesen, Helge R. [3 ]
Ketzel, Matthias [3 ]
Berkowicz, Ruwim [3 ]
Franke, Joerg [4 ]
Schatzmann, Michael [5 ]
Schluenzen, K. Heinke [5 ]
Leitl, Bernd [5 ]
Britter, Rex
Borrego, Carlos [6 ,7 ]
Costa, Ana Margarida [6 ,7 ]
Castelli, Silvia Trini [8 ]
Reisin, Tamir G. [9 ]
Hellsten, Antti [10 ]
Saloranta, Jarkko [11 ]
Moussiopoulos, Nicolas [12 ]
Barmpas, Fotios [12 ]
Brzozowski, Krzysztof [13 ]
Goricsan, Istvan [14 ]
Balczo, Marton [14 ]
Bartzis, John G. [15 ]
Efthimiou, George [15 ]
Santiago, Jose Luis [16 ]
Martilli, Alberto [16 ]
Piringer, Martin [17 ]
Baumann-Stanzer, Kathrin [17 ]
Hirtl, Marcus [17 ]
Baklanov, Alexander A. [18 ]
Nuterman, Roman B. [18 ,19 ]
Starchenko, Alexander V. [19 ]
机构
[1] Univ Salento, Dipartimento Sci Mat, I-73100 Lecce, Italy
[2] Univ Ca Foscari Venezia, Dipartimento Informat, I-30172 Venice, Italy
[3] Aarhus Univ, Natl Environm Res Inst, DK-4000 Roskilde, Denmark
[4] Univ Siegen, Dept Fluid & Thermodynam, Fac Mech Engn, D-57076 Siegen, Germany
[5] Univ Hamburg, Meteorol Inst ZMK ZMAW, D-20146 Hamburg, Germany
[6] Univ Aveiro, CESAM, P-3810193 Aveiro, Portugal
[7] Univ Aveiro, Dept Environm & Planning, P-3810193 Aveiro, Portugal
[8] CNR, Inst Atmospher Sci & Climate ISAC, I-10133 Turin, Italy
[9] Soreq Nucl Res Ctr, IL-81800 Yavne, Israel
[10] Finnish Meteorol Inst, FI-00101 Helsinki, Finland
[11] KONE Corp, FI-05801 Hyvinkaa, Finland
[12] Aristotle Univ Thessaloniki, Dept Mech Engn, Lab Heat Transfer & Environm Engn, GR-54124 Thessaloniki, Greece
[13] Univ Bielsko Biala, Dept Appl Comp Sci, PL-43309 Bielsko Biala, Poland
[14] Budapest Univ Technol & Econ BME, Dept Fluid Mech, H-1111 Budapest, Hungary
[15] Univ Western Macedonia, Dept Mech Engn, Environm Technol Lab, Kozani 50100, Greece
[16] Res Ctr Energy Environm & Technol CIEMAT, Environm Dept, Madrid 28040, Spain
[17] Cent Inst Meteorol & Geodynam, Div Customer Serv, Sect Environm Meteorol, A-1190 Vienna, Austria
[18] Danish Meteorol Inst, Meteorol Res Div, DK-2100 Copenhagen O, Denmark
[19] Tomsk State Univ, Dept Numer Math & Comp Modelling, Mech & Math Fac, Tomsk 634050, Russia
关键词
COST Action 732; CFD and non-CFD models; model evaluation; MUST; idealised urban area;
D O I
10.1504/IJEP.2011.038442
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this paper is to describe the use of a general methodology tailored to the evaluation of micro-scale meteorological models applied to flow and dispersion simulations in urban areas. This methodology, developed within COST 732, has been tested through a large modelling exercise involving many groups across Europe. The major test case used is the Mock Urban Setting Test (MUST) experiment representing an idealised urban area. It is emphasised that a full model evaluation is problem-dependent and requires several activities including a statistical validation that requires a careful choice of the metrics for the comparison with measurements.
引用
收藏
页码:403 / 418
页数:16
相关论文
共 10 条
[1]  
Bezpalcova K., 2007, PhD Thesis
[2]  
Biltoft CA, 2001, WDTCFR01121 US ARM D, P58
[3]  
Britter R., 2007, Model evaluation guidance and protocol document
[4]  
Britter R., 2007, Background and justification document to support the model evaluation guidance and protocol: COST action 732 Quality assurance and improvement of microscale meteorological models
[5]  
Carissimo B., 2007, BEST PRACTICE GUIDLI
[6]   Air quality model performance evaluation [J].
Chang, JC ;
Hanna, SR .
METEOROLOGY AND ATMOSPHERIC PHYSICS, 2004, 87 (1-3) :167-196
[7]  
*COST, 2005, QUAL ASS IMPR MICR S
[8]  
Schatzmann M., 2009, COST 732 MODEL EVALU
[9]  
*VDI, 2005, VDI GUID 9, V3783
[10]   Concentration fluctuation measurements in a plume dispersing through a regular array of obstacles [J].
Yee, E ;
Biltoft, CA .
BOUNDARY-LAYER METEOROLOGY, 2004, 111 (03) :363-415