A new chemically modified carbon paste electrode for determination of copper based on N,N'-disalicylidenehexameythylenediaminate copper(II) complex

被引:17
作者
Abu-Shawish, Hazem M. [1 ]
Saadeh, Salman M.
机构
[1] Al Aqsa Univ, Fac Sci, Gaza, Israel
[2] Islam Univ Gaza, Coll Sci, Dept Chem, Gaza, Israel
关键词
carbon paste electrode; potentiometry; copper(II) SALHMN complex;
D O I
10.1166/sl.2007.233
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new chemically modified carbon paste electrode (CMCPE) based on N,N'-disalicyliclenehexameythylenediaminate Cu(II) complex (CuSALHMN) has been developed for determination of Cu2+ in real samples. The performance of this electrode was investigated using potentiometric measurements. The developed sensor exhibits a good linear response of 31.2 +/- 1.0 mV per decade over the concentration range of 4.1 x 10(-7) - 1.0 x 10(-2) M. It has a very low limit of detection, 6.2 x 10(-8) M (3.9 ppb), with response time less than 12 s. The proposed electrode revealed very good selectivities with respect to alkali, alkaline earth and some transition metal ions and could be used in pH range of 4.0 - 6.5. This modified electrode was successfully applied as an indicator electrode for potentiometric titration Of Cu2+ with EDTA and for direct determination of copper in multivitamin tablets and tap water.
引用
收藏
页码:565 / 571
页数:7
相关论文
共 43 条
[1]   Determination of L-histidine by modified carbon paste electrode using tetra-3,4-pyridinoporphirazinatocopper(II) [J].
Abbaspour, A ;
Ghaffarinejad, A ;
Safaei, E .
TALANTA, 2004, 64 (04) :1036-1040
[2]   Chemically modified carbon paste electrode for determination of copper(II) by potentiometric method [J].
Abbaspour, A ;
Moosavi, SMM .
TALANTA, 2002, 56 (01) :91-96
[3]   Simultaneous determination of trace amounts of nickel, copper and mercury by liquid chromatography coupled with flow-injection on-line derivatization and preconcentration [J].
Ali, A ;
Shen, H ;
Yin, XF .
ANALYTICA CHIMICA ACTA, 1998, 369 (03) :215-223
[4]   COPPER SENSITIVITY OF GONYAULAX-TAMARENSIS [J].
ANDERSON, DM ;
MOREL, FMM .
LIMNOLOGY AND OCEANOGRAPHY, 1978, 23 (02) :283-295
[5]  
ARDAKANI MM, 2004, ANAL BIOANAL CHEM, V378, P1659, DOI DOI 10.1007/S00216-003-2462-4
[6]  
Bakker E, 2004, TALANTA, V63, P3, DOI 10.1016/j.talanta.2003.10.006
[7]   The new wave of ion-selective electrodes. [J].
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :420A-426A
[8]  
Bakker E, 2001, TRAC-TREND ANAL CHEM, V20, P11, DOI 10.1016/S0165-9936(00)00056-X
[9]   BEHAVIOR AND CALIBRATION OF THE COPPER(II) ION-SELECTIVE ELECTRODE IN HIGH CHLORIDE MEDIA AND MARINE WATERS [J].
BELLI, SL ;
ZIRINO, A .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2583-2589
[10]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536