Faecal bacteria and bacteriophage inactivation in a full-scale UV disinfection system used for wastewater reclamation

被引:25
作者
Bourrouet, A
García, J
Mujeriego, R
Peñuelas, G
机构
[1] Univ Politecn Catalunya, Dept Engn Hidraul Maritima & Ambiental, ETS Camins Canals & Ports, ES-08034 Barcelona, Spain
[2] Junta Sanejament, Barcelona 08036, Spain
关键词
UV disinfection; faecal bacteria; bacteriophages; somatic coliphages; water reuse; water reclamation;
D O I
10.2166/wst.2001.0616
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A study was carried out to compare the inactivation of faecal bacteria and one type of bacteriophage in a full-scale UV disinfection system. The system is part of a water reclamation facility for effluent reuse in golf course and agricultural irrigation. Influent and effluent samples were taken over two sampling periods (three consecutive days in July and one day in August), with three different UV doses applied each day (ranging from 10 to 40 mW.s/cm(2) and 20 to 80 mW.s/cm(2) in July and August, respectively). Effluent samples were also taken from a chlorine disinfection channel (5 mg Cl-2/L dose) operating in parallel to the UV system. Total coliforms (TC), faecal coliforms (FC), faecal streptoccoci (FS) and somatic coliphages (SC) were measured in each sample. F-specific RNA bacteriophages and bacteriophages of Bacteroides fragilis were also measured one day in July. The decay ratio observed for all the microorganisms was similar when UV doses applied were low (July), ranging from 1.15 to 1.25 log-units. This suggests that bacterial indicators may be suitable for virus inactivation control when low UV doses are applied; however, such low doses are inadequate to achieve effluent quality requirements for unrestricted irrigation. At higher UV doses (August), decay ratios for TC and FC were 3.1 and 2.8 log-units respectively, indicating that they were more susceptible to UV exposure than SC and FS, with decay ratios of 2.6 and 1.0 log-units, respectively. Nevertheless, these higher doses were also inadequate to achieve water quality requirements for unrestricted irrigation. The decay ratio of SC during chlorine disinfection was clearly lower than that of the other microorganisms. Bacteriophages of Bacteroides fragilis were more resistant to UV disinfection than SC and F-specific RNA. In fact, bacteriophages of Bacteroides fragilis were not affected during UV exposure. A UV dose ranging from 40 to 80 mW.s/cm2 marks the borderline beyond which inactivation rates of SC are clearly lower than those of bacterial indicators.
引用
收藏
页码:187 / 194
页数:8
相关论文
共 15 条
[1]  
APHA AWWA WEF, 1995, STAND METH EX WAT WA
[2]   DISTRIBUTION COMPARISON BETWEEN COLIPHAGES AND PHAGES OF ANAEROBIC-BACTERIA (BACTEROIDES-FRAGILIS) IN WATER SOURCES, AND THEIR RELIABILITY AS FECAL POLLUTION INDICATORS IN DRINKING-WATER [J].
ARMON, R ;
KOTT, Y .
WATER SCIENCE AND TECHNOLOGY, 1995, 31 (5-6) :215-222
[3]  
BOSCH A, 1991, J AM WATER WORKS ASS, V83, P80
[4]  
*CONS COST BRAV, 1996, 1995 O M REP
[5]  
*GEN CAT, 1988, SAN ENV ER
[6]  
HAVELAAR AH, 1991, WATER RES, V25, P529
[7]  
*ISO, 1998, ISO CD PUBL
[8]  
*ISO, 1996, ISO CD PUBL
[9]  
*ISO, 1998, ISO DIS PUBL
[10]  
LOGE FJ, 1998, WASTEWATER RECLAMATI, V10