Is endometrial pretreatment necessary in NovaSure™ 3-D endometrial ablation?

被引:10
作者
Cooper, J
Brill, A
Fulop, T
机构
[1] Univ Arizona, Sch Med, Dept Obstet & Gynecol, Phoenix, AZ USA
[2] Univ Illinois, Dept Obstet & Gynecol, Chicago, IL 60612 USA
[3] St Imre Teaching Hosp, Budapest, Hungary
关键词
ablation; bipolar; endometrial; global; medical pretreatment;
D O I
10.1046/j.1365-2508.2001.00435.x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective To assess and compare the efficacy of NovaSure, a novel 3-D bipolar endometrial ablation system, for women with severe menorrhagia secondary to dysfunctional uterine bleeding (DUB), with and without endometrial preparation. Study design A prospective, double-arm, controlled, observational pilot study of 40 women undergoing endometrial ablation using the NovaSure system. Patients 40 premenopausal women, of average age 44 years, with menorrhagia secondary to DUB and unresponsive to medical therapy, who had completed childbearing, with non-distorted uterine cavities, and cornu-to-cornu measurement of greater than 2.5 cm. Interventions Endometrial ablation using the 3-D bipolar NovaSure system. Methods 50% of the patients received gonadotrophin-releasing hormone (GnRH) agonist for endometrial thinning. The remaining patients received no treatment for endometrial thinning. Pictorial blood assessment chart (PBLAC) diary sampling was used to select patients for the study, as well as to conduct the post-treatment evaluation of menstrual blood loss and bleeding pattern (amenorrhoea, spotting, hypomenorrhea, eumenorrhoea or menorrhagia). All patients received the treatment under intravenous sedation with paracervical block. Results No intraoperative complications were observed. Treatment time averaged 72 seconds. Follow up of 12 months has been completed in 29 patients. No significant difference was observed in the outcome (i.e. efficacy) of the procedure between the two groups of patients. Conclusions Preliminary results indicate that the NovaSure system can be successfully used as an effective method of treatment for women with menorrhagia secondary to DUB. Endometrial pretreatment appears not to be necessary in global ablation performed using the NovaSure system.
引用
收藏
页码:179 / 182
页数:4
相关论文
共 8 条
[1]   COMPLICATIONS OF ABDOMINAL AND VAGINAL HYSTERECTOMY AMONG WOMEN OF REPRODUCTIVE AGE IN THE UNITED-STATES [J].
DICKER, RC ;
GREENSPAN, JR ;
STRAUSS, LT ;
COWART, MR ;
SCALLY, MJ ;
PETERSON, HB ;
DESTEFANO, F ;
RUBIN, GL ;
ORY, HW .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1982, 144 (07) :841-848
[2]   Goserelin acetate (Zoladex) plus endometrial ablation for dysfunctional uterine bleeding: A large randomized, double-blind study [J].
Donnez, J ;
Vilos, G ;
Gannon, MJ ;
StampeSorensen, S ;
Klinte, I ;
Miller, RM .
FERTILITY AND STERILITY, 1997, 68 (01) :29-36
[3]   A comparison of goserelin and danazol as endometrial thinning agents prior to endometrial laser ablation [J].
Garry, R ;
Khair, A ;
Mooney, P ;
Stuart, M .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1996, 103 (04) :339-344
[4]   ASSESSMENT OF MENSTRUAL BLOOD-LOSS USING A PICTORIAL CHART [J].
HIGHAM, JM ;
OBRIEN, PMS ;
SHAW, RW .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1990, 97 (08) :734-739
[5]   Long-term follow-up of endometrial ablation [J].
Martyn, P ;
Allan, B .
JOURNAL OF THE AMERICAN ASSOCIATION OF GYNECOLOGIC LAPAROSCOPISTS, 1998, 5 (02) :115-118
[6]   Benefit of GnRH analogue pretreatment for hysteroscopic surgery in patients with bleeding disorders [J].
Römer, T .
GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 1998, 45 :12-20
[7]   MICROWAVES FOR MENORRHAGIA - A NEW FAST TECHNIQUE FOR ENDOMETRIAL ABLATION [J].
SHARP, NC ;
CRONIN, N ;
FELDBERG, I ;
EVANS, M ;
HODGSON, D ;
ELLIS, S .
LANCET, 1995, 346 (8981) :1003-1004
[8]   Economic evaluation of hysteroscopic endometrial ablation versus vaginal hysterectomy for menorrhagia [J].
Vilos, GA ;
Pispidikis, JT ;
Botz, CK .
OBSTETRICS AND GYNECOLOGY, 1996, 88 (02) :241-245