Parallel Fourier domain optical coherence tomography for in vivo measurement of the human eye

被引:117
作者
Grajciar, B
Pircher, M
Fercher, AF
Leitgeb, RA
机构
[1] Med Univ Vienna, Ctr Biomed Engn & Phys, A-1090 Vienna, Austria
[2] Ecole Polytech Fed Lausanne, Lab Opt Biomed, CH-1015 Lausanne, Switzerland
[3] Slovak Univ Technol FEEIT, Dept Radioelectr, SK-81219 Bratislava, Slovakia
来源
OPTICS EXPRESS | 2005年 / 13卷 / 04期
关键词
D O I
10.1364/OPEX.13.001131
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A parallel Frequency Domain Optical Coherence Tomography (FD-OCT) system and - to the best of our knowledge- first in vivo tomograms obtained with such system are presented. A full tomogram of 256(x) x 512(z) pixels covering a sample region of 8 mm x 3,8 mm is recorded in only 1 ms. Since the transverse as well as the depth information is obtained in parallel, the structure is free of any motion artifacts. In order to study cross talk issues for parallel illumination the transversal resolution for a thermal light source is compared to that with an SLD. (C) 2005 Optical Society of America.
引用
收藏
页码:1131 / 1137
页数:7
相关论文
共 20 条
[1]  
American National Standards Institute, 2000, AM NAT STAND CENTR P
[2]   Full-field optical coherence microscopy [J].
Beaurepaire, E ;
Boccara, AC ;
Lebec, M ;
Blanchot, L ;
Saint-Jalmes, H .
OPTICS LETTERS, 1998, 23 (04) :244-246
[3]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[4]   A thermal light source technique for optical coherence tomography [J].
Fercher, AF ;
Hitzenberger, CK ;
Sticker, M ;
Moreno-Barriuso, E ;
Leitgeb, R ;
Drexler, W ;
Sattmann, H .
OPTICS COMMUNICATIONS, 2000, 185 (1-3) :57-64
[5]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[6]   Complex spectral interferometry OCT [J].
Fercher, AF ;
Leitgeb, R ;
Hitzenberger, CK ;
Sattmann, H ;
Wojtkowski, M .
MEDICAL APPLICATIONS OF LASERS IN DERMATOLOGY, CARDIOLOGY, OPHTHALMOLOGY, AND DENTISTRY II, PROCEEDINGS OF, 1999, 3564 :173-178
[7]  
Henderson R., 2004, Laser Safety
[8]   Spatially incoherent illumination as a mechanism for cross-talk suppression in wide-field optical coherence tomography [J].
Karamata, B ;
Lambelet, P ;
Laubscher, M ;
Salathé, RP ;
Lasser, T .
OPTICS LETTERS, 2004, 29 (07) :736-738
[9]   Video-rate three-dimensional optical coherence tomography [J].
Laubscher, M ;
Ducros, M ;
Karamata, B ;
Lasser, T ;
Salathé, R .
OPTICS EXPRESS, 2002, 10 (09) :429-435
[10]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894