Ytterbium- and dysprosium-EOB-DTPA - A new prototype of liver-specific contrast agents for computed tomography

被引:26
作者
Krause, W
SchuhmannGiampieri, G
Bauer, M
Press, WR
Muschick, P
机构
[1] Research Laboratories, Schering AG, Berlin
[2] Research Laboratories, Schering AG, 13342 Berlin
关键词
metal complexes; lanthanides; gadolinium-EOB-DTPA; ytterbium-EOB-DTPA; liver-specific iodine-free contrast agents; computed tomography;
D O I
10.1097/00004424-199608000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. A Series of studies was conducted to determine whether metal complexes of the EOB-DTPA type are useful as contrast agents for computed tomography (Cf), METHODS. Metal complexes using EOB-DTPA as ligand were synthesized with lanthanide metal ions (lanthanum [La], cerium [Ce], praseodyme [Pr], gadolinium [Gd], dysprosium [Dy], ytterbium [Yb], and lutetium [Lu]) and with nonlanthanides (lead [Pb] and bismuth [Bi]), Complex stability was assessed by measuring binding to bone meal. The physicochemical parameters partition coefficient, osmolality, viscosity, and protein binding were determined in vitro. Tolerability was tested both in vitro (thromboplastin time, effect on erythrocytes) and in vivo (acute, neural, and cardiovascular toxicities). Billary excretion and tissue distribution, especially liver, kidney, and bone concentrations, were measured in rats after intravenous doses of 0.5 mmol/kg, Imaging performance using CT was investigated in vitro in a phantom model and, for Gd-EOB-DTPA, in vivo by injecting doses of 0.5 mmol/kg into healthy or tumor-bearing rats and rabbits, RESULTS. The kinetic stability of M-EOB-DTPA complexes differed widely, Nonlanthanide metals, especially Pb-EOB-DTPA, provided less stable complexes than lanthanides with an optimum of stability for the metals Gd, Dy, Yb, and Lu, Tolerability was good for all compounds, best results were obtained for Gd and Yb, Concentrations in rat liver after administration of Gd-EOB-DTPA, 0.5 mmol/kg intravenous, were approximately 1 mu mol/g, resulting in CT enhancement of 16 Hounsfield units (HU). Tumor tissue was not enhanced, In rabbits, at the same dose level 30 HU was found, CONCLUSIONS. Metal complexes of the EOB-DTPA type, especially those of Cd and Yb seem to be useful as iodine-free liver-specific contrast agents for CT.
引用
收藏
页码:502 / 511
页数:10
相关论文
共 33 条
[1]   UNDERSTANDING AND OPTIMIZING USE OF CONTRAST MATERIAL FOR CT OF THE LIVER [J].
BARON, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :323-331
[2]   GD-DTPA AS A CONTRAST AGENT IN CT [J].
BLOEM, JL ;
WONDERGEM, J .
RADIOLOGY, 1989, 171 (02) :578-579
[3]   SPIRAL CT ARTERIAL PORTOGRAPHY OF THE LIVER [J].
BLUEMKE, DA ;
FISHMAN, EK .
RADIOLOGY, 1993, 186 (02) :576-579
[4]   COST-EFFECTIVE USE OF LOW-OSMOLALITY CONTRAST-MEDIA FOR CT OF THE LIVER - EVALUATION OF LIVER ENHANCEMENT PROVIDED BY VARIOUS DOSES OF IOHEXOL [J].
BREE, RL ;
PARISKY, YR ;
BERNARDINO, ME ;
COSTELLO, P ;
LEDER, R ;
BROWN, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) :579-583
[5]   RIGHT WINDOW FOR DYNAMIC HEPATIC CT [J].
COX, IH ;
FOLEY, WD ;
HOFFMANN, RG .
RADIOLOGY, 1991, 181 (01) :18-21
[6]   INVESTIGATION OF CONTRAST ENHANCEMENT IN CT OF THE LIVER - THE NEED FOR IMPROVED METHODS [J].
DODD, GD ;
BARON, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :643-645
[7]  
FREENY P, 1990, LIVER IMAGING
[8]  
GAZELLE GS, 1995, ACAD RADIOL, V2, P700
[9]   AN ASSESSMENT OF GD-DTPA AS A CT CONTRAST AGENT IN THE RENAL TRACT [J].
GIBSON, RJ ;
MEANOCK, CI ;
TORRIE, EPH ;
WALKER, TM .
CLINICAL RADIOLOGY, 1993, 47 (04) :278-279
[10]   PHASE-I CLINICAL-EVALUATION OF GD-EOB-DTPA AS A HEPATOBILIARY MR CONTRAST AGENT - SAFETY, PHARMACOKINETICS, AND MR-IMAGING [J].
HAMM, B ;
STAKS, T ;
MUHLER, A ;
BOLLOW, M ;
TAUPITZ, M ;
FRENZEL, T ;
WOLF, KJ ;
WEINMANN, HJ ;
LANGE, L .
RADIOLOGY, 1995, 195 (03) :785-792