Normalisation of gait EMGs: a re-examination

被引:167
作者
Burden, AM
Trew, M
Baltzopoulos, V
机构
[1] Manchester Metropolitan Univ, Crewe & Alsager Fac, Dept Exercise & Sport Sci, Alsager ST7 2HL, Cheshire, England
[2] Univ Brighton, Sch Hlth Profess, London, England
关键词
reliability; inter-individual variability; isometric MVC; isokinetic MVC;
D O I
10.1016/S1050-6411(03)00082-8
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purpose of this study was to compare four different methods of normalising electromyograms (EMGs) recorded during normal gait. Comparisons were made between the amplitude, intra-individual variability and inter-individual variability of EMGs. Surface EMGs were recorded from the biceps femoris, semitendinosus, vastus lateralis and vastus medialis of ten males and two females while they walked on a treadmill at a self-selected speed. EMGs from the same muscles were subsequently recorded during isometric maximal voluntary contractions (MVCs) and concentric, isokinetic MVCs that were performed between 0.52 and 7.85 rad.s(-1) on a BIODEX dynamometer. EMGs were also recorded during eccentric, isokinetic MVCs between 0.52 and 2.62 rad.s(-1). Gait EMGs were then normalised at 2% intervals of the gait cycle by expressing them as a percentage of the following reference values: the mean (mean dynamic method) and the peak (peak dynamic method) EMG from the intra-individual ensemble average; the EMG from an isometric MVC (isometric MVC method); and the EMG from an isokinetic MVC that occurred with the same muscle action, length and velocity of musculotendinous unit as the gait EMGs (isokinetic MVC method). The isokinetic MVC method produced significantly greater (P < 0.05) intra-individual variability compared to the other methods when it was measured using the variance ratio. Inter-individual variability of gait EMGs, again measured using the variance ratio, was also greatest when they were normalised using the isokinetic'MVC method. The pattern and amplitude of EMGs normalised using the isometric MVC method and the isokinetic MVC method were very similar (root mean square difference and absolute difference both less than 3%). It was concluded that the isokinetic MVC method should not be adopted by gait researchers or clinicians as it does not reduce intra- or inter-individual variability anymore than existing normalisation methods, nor does it provide a more representative measure of muscle activation during gait than the isometric MVC method. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:519 / 532
页数:14
相关论文
共 41 条
[1]   RELIABILITY OF MEASUREMENTS OF MUSCLE STRENGTH AND VOLUNTARY ACTIVATION USING TWITCH INTERPOLATION [J].
ALLEN, GM ;
GANDEVIA, SC ;
MCKENZIE, DK .
MUSCLE & NERVE, 1995, 18 (06) :593-600
[2]   EMG SIGNAL AMPLITUDE NORMALIZATION TECHNIQUE IN STRETCH-SHORTENING CYCLE MOVEMENTS [J].
ALLISON, GT ;
MARSHALL, RN ;
SINGER, KP .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1993, 3 (04) :236-244
[3]   Co activation and tension-regulating phenomena during isokinetic knee extension in sedentary and highly skilled humans [J].
Amiridis, IG ;
Martin, A ;
Morlon, B ;
Martin, L ;
Cometti, G ;
Pousson, M ;
vanHoecke, J .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1996, 73 (1-2) :149-156
[4]  
[Anonymous], J HUMAN MOVEMENT SCI
[5]  
ARSENAULT AB, 1986, SCAND J REHABIL MED, V18, P133
[6]  
BOBBERT MF, 1993, MED SCI SPORT EXER, V25, P251
[7]   Normalisation of EMG amplitude: an evaluation and comparison of old and new methods [J].
Burden, A ;
Bartlett, R .
MEDICAL ENGINEERING & PHYSICS, 1999, 21 (04) :247-257
[8]   AN ELECTROMYOGRAPHIC ANALYSIS OF THE KNEE DURING FUNCTIONAL ACTIVITIES .1. THE NORMAL PROFILE [J].
CICCOTTI, MG ;
KERLAN, RK ;
PERRY, J ;
PINK, M .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (05) :645-650
[9]   A GAIT ANALYSIS DATA-COLLECTION AND REDUCTION TECHNIQUE [J].
DAVIS, RB ;
OUNPUU, S ;
TYBURSKI, D ;
GAGE, JR .
HUMAN MOVEMENT SCIENCE, 1991, 10 (05) :575-587
[10]  
DAVIS RB, 1995, BIOMEDICAL ENG HDB, P381