Contrast media reactions and extravasation: Relationship to intravenous injection rates

被引:88
作者
Jacobs, JE [1 ]
Birnbaum, BA [1 ]
Langlotz, CP [1 ]
机构
[1] Univ Penn, Med Ctr, Dept Radiol, Philadelphia, PA 19104 USA
关键词
computed tomography (CT); contrast media; complications; effects;
D O I
10.1148/radiology.209.2.9807567
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the belief that the frequencies of contrast material extravasation and minor, nonidiosyncratic contrast material reactions correlate with intravenous injection rates. MATERIALS AND METHODS: Complications of 6,660 consecutive injections of contrast material for computed tomography were prospectively recorded. Ionic (n = 4,851) or nonionic (n = 1,809) contrast material was injected at 0.5-4.0 mL/sec. The injection rate was 1.9 mL/sec or less in group 1 (n = 2,899), 2.0-2.9 mL/sec in group 2 (n = 2,475) and 3.0-4.0 mL/sec in group 3 (n = 1,286). RESULTS: The extravasation rate (0.6%) did not differ significantly between the groups. The reaction rate (8.4%) also did not differ significantly between the groups. The rate of minor reactions (8.0%) was higher with ionic (9.9%) than nonionic (2.9%) contrast material (relative risk = 3.4). The rate of major reactions (0.4%) did not vary significantly with type of contrast material. The rate of nausea or vomiting (3.8%) did not differ significantly between the groups but was higher with ionic (4.9%) than nonionic (1.1%) contrast material (relative risk = 4.5). The rate of severe warmth (2.1%) was significantly higher in group 3 (2.8%) than group 1 (2.0%) or 2 (1.8%). CONCLUSION: No correlations exist between injection rate and extravasation rate or overall reaction rate.
引用
收藏
页码:411 / 416
页数:6
相关论文
共 25 条
[1]  
ANSELL G, 1980, INVESTIGATIVE RADI S, V15, P32
[2]  
Ayabe Z, 1982, Nihon Igaku Hoshasen Gakkai Zasshi, V42, P766
[3]   COMPARISON OF IOHEXOL-300 AND DIATRIZOATE MEGLUMINE-60 FOR BODY CT - IMAGE QUALITY, ADVERSE REACTIONS, AND ABORTED REPEATED EXAMINATIONS [J].
BERNARDINO, ME ;
FISHMAN, EK ;
JEFFREY, RB ;
BROWN, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (03) :665-667
[4]   EXTRAVASATION OF NONIONIC RADIOLOGIC CONTRAST-MEDIA - EFFICACY OF CONSERVATIVE TREATMENT [J].
COHAN, RH ;
DUNNICK, NR ;
LEDER, RA ;
BAKER, ME .
RADIOLOGY, 1990, 176 (01) :65-67
[5]   Extravasation of radiographic contrast material: Recognition, prevention, and treatment [J].
Cohan, RH ;
Ellis, JH ;
Garner, WL .
RADIOLOGY, 1996, 200 (03) :593-604
[6]   ACUTE REACTIONS TO UROGRAPHIC CONTRAST-MEDIA [J].
DAVIES, P ;
ROBERTS, MB ;
ROYLANCE, J .
BMJ-BRITISH MEDICAL JOURNAL, 1975, 2 (5968) :434-437
[7]   INJECTION RATE - A FACTOR IN CONTRAST REACTIONS [J].
DUDDY, MJ ;
MANNS, RA ;
WORMALD, SA .
CLINICAL RADIOLOGY, 1990, 41 (01) :42-43
[8]   EVALUATION OF PRETESTING IN PROBLEM OF SERIOUS AND FATAL REACTIONS TO EXCRETORY UROGRAPHY [J].
FISCHER, HW ;
DOUST, VL .
RADIOLOGY, 1972, 103 (03) :497-+
[9]   MORTALITY DURING EXCRETORY UROGRAPHY - MAYO-CLINIC EXPERIENCE [J].
HARTMAN, GW ;
HATTERY, RR ;
WITTEN, DM ;
WILLIAMSON, B .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (05) :919-922
[10]   SPIRAL(HELICAL) CT [J].
HEIKEN, JP ;
BRINK, JA ;
VANNIER, MW .
RADIOLOGY, 1993, 189 (03) :647-656