Comparison of spine and femur reference data in native Chinese women from different regions of China

被引:18
作者
Wu, XP
Liao, EY
Dai, RC
Shan, PF
Fang, TY
Luo, XH
Pi, YZ
Jiang, YB
机构
[1] Cent S Univ, Xiang Ya Hosp 2, Inst Metab & Endocrinol, Changsha 410011, Hunan, Peoples R China
[2] Univ Calif San Francisco, Dept Radiol, Osteoporosis & Arthrit Res Grp, San Francisco, CA 94143 USA
关键词
bone mineral density; dual-energy X-ray absorptiometry; mainland Chinese; reference data; women;
D O I
10.1007/s00198-004-1827-7
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
The aim of this study is to explore the differences of BMD reference curves at various skeletal sites among Chinese women from different regions of China and to investigate the feasibility of establishing a unified national BMD reference database for Chinese women. We measured BMD at the posteroanterior (PA) lumbar spine, femoral neck, trochanter and Ward's triangle by dual-energy X-ray absorptiometry bone densitometer in 3,422 Changsha women of South Central China, aged 20-84 years. The documented BMDs of reference populations of women in all other areas included Shanghai ( n =2,111) and Nanjing ( n =3,174) in the East, Shenyang ( n =1,213) in the Northeast, Kunming ( n =523) in the Southwest, Chongqing ( n =811) in the Midwest and Xian ( n =1,320) in the Northwest. We adopted the cubic regression as the fitting model for reference curves of BMD that varied with age, conducted conversions of BMD measured by various bone densitometers from different manufacturers and compared the differences between standardized BMD (sBMD) reference curves and combined ones for women from different areas. Our results revealed that by comparing variances in women from different areas, the average variances of non-standard BMD were 0.8-30.8% at the PA spine, 0.7-24.5% at the femoral neck, 0.6-29.9% at the trochanter and 1.1-54.7% at Ward's triangle, while average variances of sBMD either significantly decreased or disappeared (0.8-3.9% at the PA spine, 0.7-8.6% at the femoral neck, 0.6-8.3% at the trochanter and 1.1-29.9% at Ward's triangle). The sBMD reference curves were highly positive-dependent with combined ones ( r =0.913-0.999, P =0.000). At the PA spine and trochanter, the effect of combined sBMD curves presented well in women from different areas, except for those from Shanghai at the PA spine and Shenyang at the trochanter, indicating that sBMD curves were significantly different from pooled ones; at the femoral neck and Ward's triangle, the effect of combined sBMD reference curves was poor, indicating that sBMD curves demonstrated significant differences from pooled ones in women from a majority of these areas. We conclude that, in high density population areas, sBMD reference curves showed no significant geographic differences in women from various regions. In women from different areas, sBMD reference curves present good pooled results at the PA spine and trochanter. The less ideal combining effect of the sBMD curves at both femoral neck and Ward's triangle might be caused by the intrinsic differences from the different measuring instruments.
引用
收藏
页码:1215 / 1224
页数:10
相关论文
共 40 条
[1]
ANDEN NK, 1996, J BONE MINER RES, V11, P530
[2]
Bone mineral acquisition in healthy Asian, Hispanic, black, and Caucasian youth: A longitudinal study [J].
Bachrach, LK ;
Hastie, T ;
Wang, MC ;
Narasimhan, B ;
Marcus, R .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1999, 84 (12) :4702-4712
[3]
Bhudhikanok GS, 1996, J BONE MINER RES, V11, P1545
[4]
Importance of precision in bone density measurements [J].
Bonnick, SL ;
Johnston, CC ;
Kleerekoper, M ;
Lindsay, R ;
Miller, P ;
Sherwood, L ;
Siris, E .
JOURNAL OF CLINICAL DENSITOMETRY, 2001, 4 (02) :105-110
[5]
Patient assessment using standardized bone mineral density values and a national reference database: implementing uniform thresholds for the reimbursement of osteoporosis treatments in Belgium [J].
Boonen, S ;
Kaufman, JM ;
Reginster, JY ;
Devogelaer, JP .
OSTEOPOROSIS INTERNATIONAL, 2003, 14 (02) :110-115
[6]
Geographic differences in bone mineral density of Mexican women [J].
Delezé, M ;
Cons-Molina, F ;
Villa, AR ;
Morales-Torres, J ;
Gonzalez-Gonzalez, JG ;
Calva, JJ ;
Murillo, A ;
Briceño, A ;
Orozco, J ;
Morales-Franco, G ;
Peña-Rios, H ;
Guerrero-Yeo, G ;
Aguirre, E ;
Elizondo, J .
OSTEOPOROSIS INTERNATIONAL, 2000, 11 (07) :562-569
[7]
Bone density measured by dual-energy X-ray absorptiometry in healthy Kuwaiti women [J].
Dougherty, G ;
Al-Marzouk, N .
CALCIFIED TISSUE INTERNATIONAL, 2001, 68 (04) :225-229
[8]
ELDESOUKI M, 1995, SAUDI MED J, V16, P30
[9]
Discrepancies in normative data between Lunar and Hologic DXA systems [J].
Faulkner, KG ;
Roberts, LA ;
McClung, MR .
OSTEOPOROSIS INTERNATIONAL, 1996, 6 (06) :432-436
[10]
GENANT HK, 1994, J BONE MINER RES, V9, P1503