Breath-hold gadolinium-enhanced MR angiography of the major vessels at 1.0 T: Dose-response findings and angiographic correlation

被引:40
作者
Lentschig, MG
Reimer, P
Rausch-Lentschig, UL
Allkemper, T
Oelerich, M
Laub, G
机构
[1] Univ Munster, Inst Clin Radiol, D-48129 Munster, Germany
[2] Siemens AG, D-8520 Erlangen, Germany
关键词
angiography; comparative studies; aorta; MR; stenosis or obstruction; gadolinium; magnetic resonance (MR); contrast enhancement; vascular studies;
D O I
10.1148/radiology.208.2.9680558
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To find the appropriate contrast agent dose for gadolinium-enhanced magnetic resonance (MR) angiography by using individual measurements of contrast agent transit times in a randomized study. MATERIALS AND METHODS: A total of 34 patients with disease of the aorta or its major branches or both were randomly assigned to receive a dose of 0.1, 0.2, or 0.3 mmol of gadopentetate dimeglumine per kilogram of body weight. Initially, contrast agent transit times were measured with use of a turbo fast-low-angle-shot sequence. Subsequently, a three-dimensional fast imaging with steady-state precession sequence (7.3-msec repetition time, 2.8-msec echo time) was used for breath-hold MR angiography. Gadopentetate dimeglumine was injected with an MR-compatible power injector. Efficacy was evaluated by measurement of vessel enhancement and by clinical correlation of MR angiograms with x-ray angiograms. RESULTS: Evaluation of contrast agent transit time was possible in all patients with the test doses, which provided contrast-enhanced MR angiograms of constant quality. Neither vessel enhancement nor diagnostic information was significantly different across the three study groups. CONCLUSION: The clinical gadolinium dose of 0.1 mmol/kg is sufficient for diagnostic assessment of the aorta and its major branches at contrast-enhanced MR angiography. High-dose studies appear not to tie required for these large vessels.
引用
收藏
页码:353 / 357
页数:5
相关论文
共 16 条
[1]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[2]  
Edelman RR., 1996, CLIN MAGNETIC RESONA
[3]   Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries [J].
Holland, GA ;
Dougherty, L ;
Carpenter, JP ;
Golden, MA ;
Gilfeather, M ;
Slossman, F ;
Schnall, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (04) :971-981
[4]   Gadolinium-enhanced three-dimensional MR angiography of acquired arch vessel disease [J].
Krinsky, G ;
Rofsky, N ;
Flyer, M ;
Giangola, G ;
Maya, M ;
DeCoroto, D ;
Earls, J ;
Weinreb, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (04) :981-987
[5]  
LEUNG DA, 1996, RADIOLOGY, V201, P569
[6]   CLINICAL SAFETY OF GADOPENTETATE DIMEGLUMINE [J].
NELSON, KL ;
GIFFORD, LM ;
LAUBERHUBER, C ;
GROSS, CA ;
LASSER, TA .
RADIOLOGY, 1995, 196 (02) :439-443
[7]   BREATH-HOLD GADOLINIUM-ENHANCED MR-ANGIOGRAPHY OF THE ABDOMINAL-AORTA AND ITS MAJOR BRANCHES [J].
PRINCE, MR ;
NARASIMHAM, DL ;
STANLEY, JC ;
CHENEVERT, TL ;
WILLIAMS, DM ;
MARX, V ;
CHO, KJ .
RADIOLOGY, 1995, 197 (03) :785-792
[8]   DYNAMIC GADOLINIUM-ENHANCED 3-DIMENSIONAL ABDOMINAL MR ARTERIOGRAPHY [J].
PRINCE, MR ;
YUCEL, EK ;
KAUFMAN, JA ;
HARRISON, DC ;
GELLER, SC .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (06) :877-881
[9]   GADOLINIUM-ENHANCED MR AORTOGRAPHY [J].
PRINCE, MR .
RADIOLOGY, 1994, 191 (01) :155-164
[10]   GADOLINIUM-ENHANCED MAGNETIC-RESONANCE ANGIOGRAPHY OF ABDOMINAL AORTIC-ANEURYSMS [J].
PRINCE, MR ;
NARASIMHAM, DL ;
STANLEY, JC ;
WAKEFIELD, TW ;
MESSINA, LM ;
ZELENOCK, GB ;
JACOBY, WT ;
MARX, MV ;
WILLIAMS, DM ;
CHO, KJ .
JOURNAL OF VASCULAR SURGERY, 1995, 21 (04) :656-669