High-throughput data analysis for detecting and identifying differences between samples in GC/MS-based metabolomic analyses

被引:351
作者
Jonsson, P
Johansson, AI
Gullberg, J
Trygg, J
A, J
Grung, B
Marklund, S
Sjoström, M
Antti, H
Moritz, T [1 ]
机构
[1] Swedish Univ Agr Sci, Dept Forest Genet & Plant Physiol, Umea Plant Sci Ctr, SE-90187 Umea, Sweden
[2] Umea Univ, Dept Chem, Chemometr Res Grp, SE-90187 Umea, Sweden
[3] Umea Univ, Univ Umea Hosp, Dept Med Biosci, SE-90185 Umea, Sweden
[4] Univ Bergen, Dept Chem, N-5007 Bergen, Norway
关键词
D O I
10.1021/ac050601e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In metabolomics, the objective is to identify differences in metabolite profiles between samples. A widely used tool in metabolomics investigations is gas chromatography-mass spectrometry (GC/MS). More than 400 compounds can be detected in a single analysis, if overlapping GC/ MS peaks are deconvoluted. However, the deconvolution process is time-consuming and difficult to automate, and additional processing is needed in order to compare samples. Therefore, there is a need to improve and automate the data processing strategy for data generated in GC/MS-based metabolomics; if not, the processing step will be a major bottleneck for high-throughput analyses. Here we describe a new semiautomated strategy using a hierarchical multivariate curve resolution approach that processes all samples simultaneously. The presented strategy generates (after appropriate treatment, e.g., multivariate analysis) tables of all the detected metabolites that differ in relative concentrations between samples. The processing of 70 samples took similar time to that of the GC/TOFMS analyses of the samples. The strategy has been validated using two different sets of samples: a complex mixture of standard compounds and Arabidopsis samples.
引用
收藏
页码:5635 / 5642
页数:8
相关论文
共 43 条
  • [1] High-throughput classification of yeast mutants for functional genomics using metabolic footprinting
    Allen, J
    Davey, HM
    Broadhurst, D
    Heald, JK
    Rowland, JJ
    Oliver, SG
    Kell, DB
    [J]. NATURE BIOTECHNOLOGY, 2003, 21 (06) : 692 - 696
  • [2] A universal denoising and peak picking algorithm for LC-MS based on matched filtration in the chromatographic time domain
    Andreev, VP
    Rejtar, T
    Chen, HS
    Moskovets, EV
    Ivanov, AR
    Karger, BL
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (22) : 6314 - 6326
  • [3] Brindle JT, 2002, NAT MED, V8, P1439, DOI 10.1038/nm802
  • [4] Metabolomics spectral formatting, alignment and conversion tools (MSFACTs)
    Duran, AL
    Yang, J
    Wang, LJ
    Sumner, LW
    [J]. BIOINFORMATICS, 2003, 19 (17) : 2283 - 2293
  • [5] Resolution of GC-MS data of complex PAC mixtures and regression modeling of mutagenicity by PLS
    Eide, I
    Neverdal, G
    Thorvaldsen, B
    Shen, HL
    Grung, B
    Kvalheim, O
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (11) : 2314 - 2318
  • [6] Metabolomics - the link between genotypes and phenotypes
    Fiehn, O
    [J]. PLANT MOLECULAR BIOLOGY, 2002, 48 (1-2) : 155 - 171
  • [7] Objective data alignment and chemometric analysis of comprehensive two-dimensional separations with run-to-run peak shifting on both dimensions
    Fraga, CG
    Prazen, BJ
    Synovec, RE
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (24) : 5833 - 5840
  • [8] Metabolomics by numbers: acquiring and understanding global metabolite data
    Goodacre, R
    Vaidyanathan, S
    Dunn, WB
    Harrigan, GG
    Kell, DB
    [J]. TRENDS IN BIOTECHNOLOGY, 2004, 22 (05) : 245 - 252
  • [9] Design of experiments:: an efficient strategy to identify factors influencing extraction and derivatization of Arabidopsis thaliana samples in metabolomic studies with gas chromatography/mass spectrometry
    Gullberg, J
    Jonsson, P
    Nordström, A
    Sjöström, M
    Moritz, T
    [J]. ANALYTICAL BIOCHEMISTRY, 2004, 331 (02) : 283 - 295
  • [10] Halket JM, 1999, RAPID COMMUN MASS SP, V13, P279, DOI 10.1002/(SICI)1097-0231(19990228)13:4<279::AID-RCM478>3.0.CO