Detection of bacteria in suspension by using a superconducting quantum interference device

被引:150
作者
Grossman, HL
Myers, WR
Vreeland, VJ
Bruehl, R
Alper, MD
Bertozzi, CR
Clarke, J
机构
[1] Univ Calif Berkeley, Dept Phys, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Dept Mol & Cell Biol, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Howard Hughes Med Inst, Berkeley, CA 94720 USA
[4] Lawrence Berkeley Lab, Div Mat Sci, Berkeley, CA 94720 USA
[5] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
关键词
D O I
10.1073/pnas.0307128101
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We demonstrate a technique for detecting magnetically labeled Listeria monocytogenes and for measuring the binding rate between antibody-linked magnetic particles and bacteria. This sensitive assay quantifies specific bacteria in a sample without the need to immobilize them or wash away unbound magnetic particles. In the measurement, we add 50-nm-diameter superparamagnetic magnetite particles, coated with antibodies, to an aqueous sample containing L. monocytogenes. We apply a pulsed magnetic field to align the magnetic dipole moments and use a high-transition temperature superconducting quantum interference device, an extremely sensitive detector of magnetic flux, to measure the magnetic relaxation signal when the field is turned off. Unbound particles randomize direction by Brownian rotation too quickly to be detected. In contrast, particles bound to L. monocytogenes are effectively immobilized and relax in about 1 s by rotation of the internal dipole moment. This Neel relaxation process is detected by the superconducting quantum interference device. The measurements indicate a detection limit of (5.6 +/- 1.1) x 10(6) L. monocytogenes in our sample volume of 20 mul. If the sample volume were reduced to 1 nl, we estimate that the detection limit could be improved to 230 +/- 40 L. monocytogenes cells. Time resolved measurements yield the binding rate between the particles and bacteria.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 31 条
[1]   A high-sensitivity micromachined biosensor [J].
Baselt, DR ;
Lee, GU ;
Hansen, KM ;
Chrisey, LA ;
Colton, RJ .
PROCEEDINGS OF THE IEEE, 1997, 85 (04) :672-680
[2]   A biosensor based on magnetoresistance technology [J].
Baselt, DR ;
Lee, GU ;
Natesan, M ;
Metzger, SW ;
Sheehan, PE ;
Colton, RJ .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (7-8) :731-739
[3]  
Berg H. C., 1983, RANDOM WALKS BIOL
[4]   Irreversible relaxation behaviour of a general class of magnetic systems [J].
Berkov, DV ;
Kotitz, R .
JOURNAL OF PHYSICS-CONDENSED MATTER, 1996, 8 (09) :1257-1266
[5]   Detection of a single magnetic microbead using a miniaturized silicon Hall sensor [J].
Besse, PA ;
Boero, G ;
Demierre, M ;
Pott, V ;
Popovic, R .
APPLIED PHYSICS LETTERS, 2002, 80 (22) :4199-4201
[6]   Ultrasensitive magnetic biosensor for homogeneous immunoassay [J].
Chemla, YR ;
Crossman, HL ;
Poon, Y ;
McDermott, R ;
Stevens, R ;
Alper, MD ;
Clarke, J .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (26) :14268-14272
[7]   Microfabricated devices in biotechnology and biochemical processing [J].
Chován, T ;
Guttman, A .
TRENDS IN BIOTECHNOLOGY, 2002, 20 (03) :116-122
[8]  
Clarke J, 1996, NATO ADV SCI I E-APP, V329, P1
[9]  
Debye P., 1929, Polar Molecules
[10]  
Elbing K., 2002, Current Protocols in Molecular Biology, V3rd