Trace elements and micropollutant anions in the dialysis and reinfusion fluid prepared on-line for haemodiafiltration

被引:8
作者
Surian, M
Bonforte, G
Scanziani, R
Dozio, B
Baj, A
Della Vedova, L
Toffoletto, F
机构
[1] Osped Desio, Div Nephrol & Dialisi, I-20033 Milan, Italy
[2] Osped Desio, Serv Med Lavoro, I-20033 Milan, Italy
[3] PMIP Parabiago, Unita Chim, Milano, Italy
关键词
dialysis fluids; micropollutants; on-line haemodiafiltration; reinfusion fluids; trace elements;
D O I
10.1093/ndt/13.suppl_5.24
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Exposure to the trace elements and micropollutions of tap water may be very considerable in dialysis patients. As few data on trace elements in reinfusion and dialysis fluid for haemodiafiltration (HDF) have been reported, we studied nine trace elements (mu g/l; Al, As, Cd, Cr, Cu, He, Pb, Se, Zn) and five anions (mg/l; F-, NO2-, NO3-, PO43-, SO42-) in tap water, in water after two passages of reverse osmosis (2RO), in dialysate and in on-line prepared reinfusate. NO3- and SO42- were somewhat elevated in our tap water (22.2 +/- 7.6 and 21.8 +/- 11.3 mg/l) but decreased (P < 0.001) after 2RO (1.4 +/- 1.5 and 0.9 +/- 1.1 mg/l); the other anions, which were at a very low level, remained unchanged. All trace elements decreased, with statistical significance only for Al, Cr and Zn from 14.9 +/- 19.9, 2.6 +/- 0.6 and 35.1 +/- 41.1 mu g/l to 3.2 +/- 2.1, 0.2 +/- 0.2 and 3.5 +/- 4.8 mu g/l, respectively. Due to impurities in concentrate salts for Al (5.4 +/- 3.1), Cr (0.5 +/- 0.4) and SO42- (2.4 +/- 1.8), greater concentrations were found in dialysate and reinfusate than in tap water after 2RO (P < 0.03). For all measurements, trace elements and anions were at acceptable levels according to international standards. Simultaneous determinations of trace elements at inflow (Din) and outflow (Dout) of the dialysate as well as in plasma or in whole blood at the beginning of on-line HDF documented Dout/Din > 1 for Al, Cu and Zn and a positive gradient between the concentration in blood and dialysate inlet. In conclusion, our dialysate and reinfusate can be considered safe regarding trace elements and micropollution: two passages through reverse osmosis reduces the concentrations of trace elements and anions. The impurities of concentrates are acceptable. Accumulation or depletion of trace elements should be evaluated after longitudinal studies of plasma concentrations.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 23 条
[1]  
AISEN P, 1969, J BIOL CHEM, V244, P4628
[2]  
Alfrey A. C., 1986, KIDNEY INT, V29, P53
[3]  
ALFREY AC, 1989, REPLACEMENT RENAL FU, P996
[4]  
*APHA AWWA WPCF, 1989, 4110B APHA AWWA WPCF, P2
[5]   Plasma or whole blood concentrations of trace elements in patients treated by haemodiafiltration with on-line prepared substitution fluid [J].
Bonforte, G ;
Surian, M ;
Dozio, B ;
Scanziani, R ;
Baj, A ;
Colombo, S ;
Toffoletto, F .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 :29-33
[6]  
BONFORTE G, 1995, NOSTRA CURA 15 SCRIT, P63
[7]   HEMODIALYSIS WITH REGENERATED CELLULOSIC MEMBRANES DOES NOT REDUCE PLASMA SELENIUM LEVELS IN CHRONIC UREMIC PATIENTS [J].
BONOMINI, M ;
MANFRINI, V ;
MARINI, A ;
DERISIO, F ;
NIRI, L ;
KLINKMANN, H ;
ALBERTAZZI, A .
ARTIFICIAL ORGANS, 1995, 19 (01) :81-85
[8]  
CANAUD B, 1994, CONTRIB NEPHROL, V12, P108
[9]  
CLYNE N, 1989, TRACE ELEM MED, V6, P37
[10]  
CORNELIS R, 1984, P 5 INT S TRAC EL ME