Arterial phase carotid and vertebral artery imaging in 3D contrast-enhanced MR angiography by combining fluoroscopic triggering with an elliptical centric acquisition order

被引:63
作者
Wilman, AH [1 ]
Riederer, SJ [1 ]
Huston, J [1 ]
Wald, JT [1 ]
Debbins, JP [1 ]
机构
[1] Mayo Clin & Mayo Fdn, MR Lab, Dept Diagnost Radiol, Rochester, MN 55905 USA
关键词
carotid arteries; MR angiography; contrast-enhanced; MR fluoroscopy;
D O I
10.1002/mrm.1910400104
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Arterial-phase three-dimensional (3D) contrast-enhanced MR angiograms of the carotid and vertebral arteries from their origins through the carotid bifurcations were obtained in 20 patients using acquisition times over 30 sec by using an MR fluoroscopy-triggered pulse sequence with elliptical centric view order. The typical pixel size was 0.8 mm (x) x 1.6 mm (y) x 1.5 mm (z), and 32-48 coronal slices were acquired. The fluoroscopic monitoring of bolus arrival was effective in 18 of the 20 cases; two failures were attributed directly to a poor choice of RF coil, To exploit peak arterial-to-venous contrast, the central 3D views were acquired first in the most compact time period possible for the given TR. For the 18 successfully triggered cases, arterial-phase 3D images were obtained with excellent venous suppression as demonstrated by an average internal jugular vein to common carotid signal enhancement ratio of only 0.05 +/- 0.04.
引用
收藏
页码:24 / 35
页数:12
相关论文
共 44 条
[1]   DYNAMIC CONTRAST-ENHANCED SUBTRACTION MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES - INITIAL EVALUATION WITH A MULTISECTION 2-DIMENSIONAL TIME-OF-FLIGHT SEQUENCE [J].
ADAMIS, MK ;
LI, W ;
WIELOPOLSKI, PA ;
KIM, D ;
SAX, EJ ;
KENT, KC ;
EDELMAN, RR .
RADIOLOGY, 1995, 196 (03) :689-695
[2]  
ANDERSON C, 1993, CLINICAL MAGNETIC RE
[3]   CENTRIC PHASE-ENCODING ORDER IN 3-DIMENSIONAL MP-RAGE SEQUENCES - APPLICATION TO ABDOMINAL IMAGING [J].
BAMPTON, AEH ;
RIEDERER, SJ ;
KORIN, HW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03) :327-334
[4]  
BOOS M, 1997, P ISMRM 5 ANN M VANC, P204
[5]   MR-IMAGING OF THE ABDOMEN WITH A PHASED-ARRAY MULTICOIL - PROSPECTIVE CLINICAL-EVALUATION [J].
CAMPEAU, NG ;
JOHNSON, CD ;
FELMLEE, JP ;
RYDBERG, JN ;
BUTTS, RK ;
EHMAN, RL ;
RIEDERER, SJ .
RADIOLOGY, 1995, 195 (03) :769-776
[6]   NORMAL VENOUS ANATOMY OF THE BRAIN - DEMONSTRATION WITH GADOPENTETATE DIMEGLUMINE IN ENHANCED 3-D MR ANGIOGRAPHY [J].
CHAKERES, DW ;
SCHMALBROCK, P ;
BROGAN, M ;
YUAN, C ;
COHEN, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (01) :161-172
[7]   3D gadolinium-enhanced MR angiography of the carotid arteries [J].
Cloft, HJ ;
Murphy, KJ ;
Prince, MR ;
Brunberg, JA .
MAGNETIC RESONANCE IMAGING, 1996, 14 (06) :593-600
[8]   GADOLINIUM-ENHANCED MR ANGIOGRAPHY [J].
CREASY, JL ;
PRICE, RR ;
PRESBREY, T ;
GOINS, D ;
PARTAIN, CL ;
KESSLER, RM .
RADIOLOGY, 1990, 175 (01) :280-283
[9]   Cardiac magnetic resonance fluoroscopy [J].
Debbins, JP ;
Riederer, SJ ;
Rossman, PJ ;
Grimm, RC ;
Felmlee, JP ;
Breen, JF ;
Ehman, RL .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :588-595
[10]  
DEBBINS JP, 1997, P ISMRM 5 ANN M VANC, P1819