Direct-space methods in phase extension and phase refinement .4. The double-histogram method

被引:16
作者
Refaat, LS
Tate, C
Woolfson, MM
机构
[1] Physics Department, University of York, Heslington
来源
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY | 1996年 / 52卷
关键词
D O I
10.1107/S0907444995008456
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the conventional histogram-matching technique for phase extension and refinement for proteins a simple one-to-one transformation is made in the protein region to modify calculated density so that it will have some target histogram in addition to solvent flattening. This work describes an investigation where the density modification takes into account not only the current calculated density at a grid point but also some characteristic of the environment of the grid point within some distance R. This characteristic can be one of the local maximum density, the local minimum density or the local variance of density. The grid points are divided into ten groups, each containing the same number of grid points, for ten different ranges of value of the local characteristic. The ten groups are modified to give different histograms, each corresponding to that obtained under the same circumstances from a structure similar to the one under investigation. This process is referred to as the double-histogram matching method. Other processes which have been investigated are the weighting of structure factors when calculating maps with estimated phases and also the use of a factor to dampen the change of density and so control the refinement process. Two protein structures were used in numerical trials, RNAp1 [Bezborodova, Ermekbaeva, Shlyapnikov, Polyakov & Bezborodov (1988). Biokhimiya, 53, 965-973] and 2-Zn insulin [Baker, Blundell, Cutfield, Cutfield, Dodson, Dodson, Hodgkin, Hubbard, Isaacs, Reynolds, Sakabe, Sakabe & Vijayan (1988). Philos. Trans. R. Sec. London Ser. B, 319, 456-469]. Comparison of the proposed procedures with the normal histogram-matching technique without structure-factor weighting or damping gives mean phase errors reduced by up to 10 degrees with map correlation coefficients improved by as much as 0.14. Compared to the normal histogram used with weighting of structure factors and damping, the improvement due to the use of the double-histogram method is usually of order 4 degrees in mean phase error and an increase of 0.06-0.08 in the map correlation coefficient. It is concluded that the most reliable results are found with the local-maximum condition and with R in the range 0.5-0.6 Angstrom.
引用
收藏
页码:252 / 256
页数:5
相关论文
共 13 条
[1]  
BAKER EN, 1988, PHILOS T R SOC LON B, V319, P456
[2]  
BEZBORODOVA S I, 1988, Biokhimiya, V53, P965
[3]  
GU Y, 1996, UNPUB
[4]   ELECTRON-DENSITY HISTOGRAMS AND THE PHASE PROBLEM [J].
LUNIN, VY .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 1993, 49 :90-99
[5]   MEAN PHASE ERROR AND THE MAP CORRELATION-COEFFICIENT [J].
LUNIN, VY ;
WOOLFSON, MM .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 1993, 49 :530-533
[6]   DIRECT-SPACE METHODS IN PHASE EXTENSION AND PHASE DETERMINATION .2. DEVELOPMENTS OF LOW-DENSITY ELIMINATION [J].
REFAAT, LS ;
WOOLFSON, MM .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 1993, 49 :367-371
[7]  
REFAAT LS, 1996, IN PRESS
[9]   LEAST-SQUARES PHASE REFINEMENT .2. HIGH-RESOLUTION PHASING OF A SMALL PROTEIN [J].
SAYRE, D .
ACTA CRYSTALLOGRAPHICA SECTION A, 1974, A 30 (MAR) :180-184
[10]   DIRECT-SPACE METHODS IN PHASE EXTENSION AND PHASE DETERMINATION .1. LOW-DENSITY ELIMINATION [J].
SHIONO, M ;
WOOLFSON, MM .
ACTA CRYSTALLOGRAPHICA SECTION A, 1992, 48 :451-456