Double-fed induction machine: converter optimisation and field oriented control without position sensor

被引:149
作者
Morel, L
Godfroid, H
Mirzaian, A
Kauffmann, JM
机构
[1] Ctr Rech Electrotech & Elect Belfort, F-90008 Belfort, France
[2] CEGELEC, F-90018 Belfort, France
[3] Inst Genie Energet, Parc Technol, F-90000 Belfort, France
来源
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS | 1998年 / 145卷 / 04期
关键词
converter sizing; variable-speed systems; double-fed induction machines; field-oriented control;
D O I
10.1049/ip-epa:19981982
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The authors present a new system for variable speed using a double-fed induction machine. With a special operating mode, the apparent power of the inverter can reach only 20% of the maximum mechanical power, compared to a classical solution which needs 120%. Control laws are also studied with and without a sensor and they are particularly robust. The approach is validated by simulations and experimental results.