Positive or negative blips? The effect of phase encoding scheme on susceptibility-induced signal losses in EPI

被引:47
作者
De Panfilis, C
Schwarzbauer, C
机构
[1] Univ Cambridge, Addenbrookes Hosp, Wolfson Brain Imaging Ctr, Cambridge CB2 2QQ, England
[2] MRC, Cognit & Brain Sci Unit, Cambridge, England
[3] Univ Cambridge, Dept Psychiat, Cambridge CB2 2QQ, England
基金
英国医学研究理事会;
关键词
fMRI; susceptibility artifacts; EPI;
D O I
10.1016/j.neuroimage.2004.11.014
中图分类号
Q189 [神经科学];
学科分类号
071006 [神经生物学];
摘要
The observation of blood oxygenation level-dependent (BOLD) effect in functional magnetic resonance imaging (fMRI) studies is often hampered by the presence of magnetic field in homogeneities. These are caused by abrupt changes in the magnetic susceptibility that typically occur near air/tissue interfaces and may result in substantial image distortions and signal losses. In this article, we investigate the effect of susceptibility-induced magnetic field inhomogeneities on the signal intensity (1) and the BOLD sensitivity (BS) for two different phase encoding schemes in blipped echo-planar imaging (EPI), which use either positive (EPIpos) or negative (EPIneg) phase gradient blips for stepping through k-space. Based on magnetic field maps, we generate computer simulations of I and BS for both phase encoding schemes and demonstrate good agreement with the experimental image intensities. We show that regions compromised by susceptibility effects are affected very differently by EPIpos, and EPIneg. Further simulations are performed in two representative regions of interest (orbitofrontal cortex and lower temporal lobe) to investigate the dependence of I and BS on the slice angle (alpha), the magnitude of a moderate compensation gradient applied in the slice direction (G(s)(comp)), and the phase encoding scheme. We find that I and BS can be considerably increased if the appropriate phase encoding scheme is applied in addition to optimizing alpha and G(s)(comp). Our results suggest that this optimization method would be useful in future fMRI studies to improve the sensitivity in regions compromised by susceptibility effects. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:112 / 121
页数:10
相关论文
共 29 条
[1]
REDUCTION OF SUSCEPTIBILITY ARTIFACT IN GRADIENT-ECHO IMAGING [J].
CHO, ZH ;
RO, YM .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :193-200
[2]
Single-shot T*2 measurement to establish optimum echo time for fMRI:: Studies of the visual, motor, and auditory cortices at 3.0 T [J].
Clare, S ;
Francis, S ;
Morris, PG ;
Bowtell, R .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) :930-933
[3]
Constable RT, 1999, MAGNET RESON MED, V42, P110, DOI 10.1002/(SICI)1522-2594(199907)42:1<110::AID-MRM15>3.0.CO
[4]
2-3
[5]
An evaluation of the use of magnetic field maps to undistort echo-planar images [J].
Cusack, R ;
Brett, M ;
Osswald, K .
NEUROIMAGE, 2003, 18 (01) :127-142
[6]
Compensation of susceptibility-induced BOLD sensitivity losses in echo-planar fMRI Imaging [J].
Deichmann, R ;
Josephs, O ;
Hutton, C ;
Corfield, DR ;
Turner, R .
NEUROIMAGE, 2002, 15 (01) :120-135
[7]
Optimized EPI for fMRI studies of the orbitofrontal cortex [J].
Deichmann, R ;
Gottfried, JA ;
Hutton, C ;
Turner, R .
NEUROIMAGE, 2003, 19 (02) :430-441
[8]
Susceptibility-induced loss of signal: Comparing PET and fMRI on a semantic task [J].
Devlin, JT ;
Russell, RP ;
Davis, MH ;
Price, CJ ;
Wilson, J ;
Moss, HE ;
Matthews, PM ;
Tyler, LK .
NEUROIMAGE, 2000, 11 (06) :589-600
[9]
DIRECT FLASH MR IMAGING OF MAGNETIC-FIELD INHOMOGENEITIES BY GRADIENT COMPENSATION [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (04) :474-480
[10]
Glover G.H., 1998, P 6 ANN M ISMRM SYDN, P298