Mersilene mesh sling: Short- and long-term clinical and urodynamic outcomes

被引:29
作者
Young, SB [1 ]
Howard, AE [1 ]
Baker, SP [1 ]
机构
[1] UMass Mem Hlth Care, Div Urogynecol & Reconstruct Pelv Surg, Dept Obstet & Gynecol, Worcester, MA 01655 USA
关键词
sling; incontinence; genuine stress incontinence; Mersilene mesh sling; stress incontinence surgery;
D O I
10.1067/mob.2001.116370
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: We sought to determine the long-term efficacy, safety, and urodynamic effects of the Mersilene mesh suburethral sling in treating complicated forms of genuine stress incontinence. STUDY DESIGN: Two hundred women diagnosed with genuine stress incontinence, complicated by recurrence, intrinsic sphincter deficiency, or chronically increased intraabdominal pressure underwent a suburethral mesh sling procedure (Mersilene; Ethicon Inc, Somerville, NJ). They were monitored with yearly clinical examinations plus short- and long-term postoperative urodynamic evaluations; statistical analysis was carried out by use of the Friedman 2-way analysis by rank, Fischer-Freeman-H alton exact testing, analysis of variance for repeated measures, Wilcoxon, exact Mann-Whitney U test, and Bonferroni paired t test. Of 176 patients who were 5 months or more postop, 127 (72%) had preoperative and short-term postoperative urodynamic evaluations (range 5 to 23 months, mean 12.6 months). Fifty-two of 117 women who were more than 19 months postop (44%) completed preoperative and long-term postoperative urodynamic evaluations at a mean of 63 months (range 20 to 107). One hundred thirty-six of 176 patients (77%) who were more than 4 months postop had a short- and/or long-term postoperative urodynamic evaluation (range 5 to 107 months, mean 30 months). RESULTS: Objective cure rate by stress test was 93% (126 of 136 patients) at a mean of 30 months followup. The long-term objective cure rate was 94% (49 of 52). Subjectively, the short- and long-term cure rates were 95.3% and 90.4%, respectively. The cotton swab angle deflection decreased by a mean of 54 degrees at 1 year and 50 degrees at 5 years. Of the 10 failures, the mean preoperative cotton swab straining angle was 19.6 degrees, with 6 being < 30 degrees. Nineteen patients had a negative preoperative, cotton swab angle test result (mean straining angle 15 degrees before operation, -6 degrees after operation) and a longterm cure rate of 67%. The objective cure rate in patients with positive cotton swab angle results monitored long term (mean 62 months) was 100% (41 of 41). The postvoid residual increased by a mean of 25 mL short term and 10 mL long term. Thirty-eight patients (19%) had a total of 43 complications. Seven patients (3.5%) had long-term retention. De novo detrusor instability occurred in 12 patients (8.8%), although it was cured in 6 (4.4%). Eight patients (4%) had vaginal or inguinal sling erosion and were healed after revision, Delayed healing at the vaginal sling site responded completely to estrogen cream in two (1 %) patients. Five women had treatable vaginal stenosis, 5 had a local inguinal collection/infection unrelated to the mesh, and 3 required a 2-unit transfusion of packed red blood cells. One patient each had an entrapped nerve released, a cystotomy repaired, or experienced thigh numbness or groin pain. CONCLUSIONS: The suburethral Mersilene mesh sling has a very high long-term objective and subjective cure rate in the treatment of complicated forms of genuine stress incontinence. Frequent complications do occur but are remediable. The 33% failure rate among patients with a preoperative negative cotton swab angle test result and the very low cotton swab straining angle among the 7% who had sling failures further confirms the widely held belief that sling urethropexy in the absence of hypermobility lacks efficacy.
引用
收藏
页码:32 / 40
页数:9
相关论文
共 29 条
[1]  
Abrams P, 1990, INT UROGYNECOL J, V1, P45
[2]   Primary slings for everyone with genuine stress incontinence? The Argument for ... [J].
R. A. Appell .
International Urogynecology Journal, 1998, 9 (5) :249-251
[3]  
BERGMAN A, 1989, J REPROD MED, V34, P193
[4]   Sling techniques in the treatment of genuine stress incontinence [J].
Bidmead, J ;
Cardozo, L .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2000, 107 (02) :147-156
[5]   Pubovaginal fascial sling for all types of stress urinary incontinence: Long-term analysis [J].
Chaikin, DC ;
Rosenthal, J ;
Blaivas, JG .
JOURNAL OF UROLOGY, 1998, 160 (04) :1312-1316
[6]   A FOLLOW-UP OF SILASTIC SLING FOR GENUINE STRESS-INCONTINENCE [J].
CHIN, YK ;
STANTON, SL .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1995, 102 (02) :143-147
[7]   Our experience with pubovaginal slings in patients with stress urinary incontinence [J].
Cross, CA ;
Cespedes, RD ;
McGuire, EJ .
JOURNAL OF UROLOGY, 1998, 159 (04) :1195-1198
[8]   STRUCTURAL SUPPORT OF THE URETHRA AS IT RELATES TO STRESS URINARY-INCONTINENCE - THE HAMMOCK HYPOTHESIS [J].
DELANCEY, JOL .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1994, 170 (06) :1713-1723
[9]  
GHONIEM GM, 1994, INT UROGYNECOL J, V5, P228
[10]   MAXIMUM AND AVERAGE URINE FLOW-RATES IN NORMAL-MALE AND FEMALE POPULATIONS - THE LIVERPOOL NOMOGRAMS [J].
HAYLEN, BT ;
ASHBY, D ;
SUTHERST, JR ;
FRAZER, MI ;
WEST, CR .
BRITISH JOURNAL OF UROLOGY, 1989, 64 (01) :30-38