Flow injection preconcentration by chemofiltration and spectrophotometric determination of Gd

被引:9
作者
De Vito, IE
Olinsa, RA
Raba, J
Masi, AN
机构
[1] Natl Univ San Luis, Fac Chem Biochem & Pharm, Dept Analyt Chem, RA-5700 San Luis, Argentina
[2] Consejo Nacl Invest Cient & Tecn, RA-1033 Buenos Aires, DF, Argentina
关键词
flow injection; preconcentration and determination; absorptiornetric method; gadolinium in urine sample;
D O I
10.1016/j.aca.2003.06.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new on-line Gd preconcentration and determination system associated to flow injection (FI) method was developed. 2,2'-(1,8-dihydroxy3,6-disulfonaphthylene-2,7-bisazo) bisbenzenearsonic acid (Arsenazo III) was used as a complexing agent at pH 2.5. A reactor containing the polyamide membrane was used for the retention of the Gd complex by chemofiltration. The complex was then removed from the reactor with buffer solution pH 9. The variables affecting the combined on-line preconcentration-absorptiometric method have been evaluated and optimised. The coupling of the on-line preconcentration and spectrophotometric flow through detection led to a detection limit of 15 mug l(-1) for a preconcentration time of 5 min at 2 ml/min. The method was successfully applied to biological samples. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:11 / 16
页数:6
相关论文
共 13 条
[1]   SEPARATION AND PRECONCENTRATION OF THE RARE-EARTH ELEMENTS AND YTTRIUM FROM GEOLOGICAL-MATERIALS BY ION-EXCHANGE AND SEQUENTIAL ACID ELUTION [J].
CROCK, JG ;
LICHTE, FE ;
RIDDLE, GO ;
BEECH, CL .
TALANTA, 1986, 33 (07) :601-606
[2]   Preconcentration and elimination of matrix effects in XRF determinations of rare earth elements by preparing a thin film through chemofiltration [J].
De Vito, IE ;
Olsina, RA ;
Masi, AN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (03) :275-278
[3]  
DENG RW, 1992, B SOC CHIM BELG, V101, P438
[4]  
Evans C.H., 1990, BIOCH LANTHANIDES
[5]  
HOCINE N, 1995, CELL MOL BIOL, V41, P271
[6]   REVIEW OF METHODS FOR THE DETERMINATION OF LANTHANIDES IN GEOLOGICAL SAMPLES [J].
KANTIPULY, CJ ;
WESTLAND, AD .
TALANTA, 1988, 35 (01) :1-13
[7]  
Marczenko Z., 1976, SPECTROPHOTOMETRIC D
[8]  
MOTTOLA HA, 1988, KINETIC ASPECTS ANAL, P67
[9]   On-line preconcentration system for bismuth determination in urine by flow injection hydride generation inductively coupled plasma atomic emission spectrometry [J].
Moyano, S ;
Wuilloud, RG ;
Olsina, RA ;
Gásquez, JA ;
Martinez, LD .
TALANTA, 2001, 54 (02) :211-219
[10]  
REICHERT DE, 1990, COORDIN CHEM REV, V184, P3