Low order PWM inverter harmonics contributions to the inverter-fed induction machine fault diagnosis

被引:100
作者
Akin, Bilal [1 ]
Orguner, Urnut [2 ]
Toliyat, Hamid A. [1 ]
Rayner, Mark [3 ]
机构
[1] Texas A&M Univ, Dept Elect & Comp Engn, College Stn, TX 77843 USA
[2] Middle E Tech Univ, Dept Elect & Elect Engn, TR-06531 Ankara, Turkey
[3] Toshiba Ind Corp, Houston, TX 77041 USA
关键词
bearing faults; condition monitoring; current signature analysis; fault diagnosis; inverter harmonics; spectral analysis;
D O I
10.1109/TIE.2007.911954
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, the effects of inverter harmonies on motor current fault signatures are studied in detail. It is theoretically and experimentally shown that the fault signatures caused by the inverter harmonies are similar and comparable to those generated by the fundamental harmonic on the line current. Theoretically-derived extended relations including bearing fault, eccentricity, and broken rotor bar relations are found to match experimental results. Furthermore, it is observed and reported that the asymmetries on the rotor caused by broken rotor bars increase the amplitude of even harmonies. To confirm these claims, bearing, eccentricity, and broken rotor bar faults are tested and the line current spectrum of each faulty motor is compared with the healthy one. The proposed additional fault data are expected to contribute positively to the inverter-fed motor fault decision-making algorithms.
引用
收藏
页码:610 / 619
页数:10
相关论文
共 25 条
[1]   Phase sensitive detection of motor fault signatures in the presence of noise [J].
Akin, Bilal ;
Toliyat, Hamid ;
Orguner, Umut ;
Rayner, Mark .
IEEE IEMDC 2007: PROCEEDINGS OF THE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, VOLS 1 AND 2, 2007, :1420-+
[2]  
[Anonymous], 1965, NATURE INDUCTION MAC
[3]   Multiple signature processing-based fault detection schemes for broken rotor bar in induction motors [J].
Ayhan, B ;
Chow, MY ;
Song, MH .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (02) :336-343
[4]   Multiple discriminant analysis and neural-network-based monolith and partition fault-detection schemes for broken rotor bar in induction motors [J].
Ayhan, Bulent ;
Chow, Mo-Yuen ;
Song, Myung-Hyun .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (04) :1298-1308
[5]   Quantitative evaluation of induction motor broken bars by means of electrical signature analysis [J].
Bellini, A ;
Filippetti, F ;
Franceschini, G ;
Tassoni, C ;
Kliman, GB .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (05) :1248-1255
[6]   Effects of rotor bar and end-ring faults over the signals of a position estimation strategy for induction motors [J].
Bossio, GR ;
De Angelo, CH ;
García, GO ;
Solsona, JA ;
Valla, MI .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (04) :1005-1012
[7]  
Briz F, 2004, IEEE T IND APPL, V40, P1153, DOI [10.1109/TIA.2004.830792, 10.1109/tia.2004.830792]
[8]   Simulation and analysis of induction machines with rotor asymmetries [J].
Cunha, CCM ;
Lyra, ROC ;
Cardoso, B .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (01) :18-24
[9]   Analysis of airgap flux, current, and vibration signals as a function of the combination of static and dynamic airgap eccentricity in 3-phase induction motors [J].
Dorrell, DG ;
Thomson, WT ;
Roach, S .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (01) :24-34
[10]  
Duque O., 2005, International Electric Machines and Drives Conference (IEEE Cat. No.05EX1023C), P17, DOI 10.1109/IEMDC.2005.195695